• 5 •
The continuous load demand from the equipment or device
3.
being operated exceeds the continuous load rating of the
inverter being used. Solution: use a higher capacity inverter or
lower rated device.
The case temperature becomes hot (exceeds 145°F).
4.
Solution: allow the inverter to cool. Do not block the cooling
slots or air flow over and through the inverter. Reduce the load
on the inverter to the continuous rated output.
RESET:
To reset after shutdown occurs, remove the 12-volt plug from
the accessory outlet. Check the source of the problem and correct.
Reinsert the 12-volt plug into the accessory outlet.
IF THE INVERTER FUSE BLOWS
7.
Your power inverter is fitted with a fuse, which should not have to be
replaced under normal operating conditions. A blown fuse is usually
caused by reverse polarity or a short circuit within the device or
equipment being operated.
If the fuse does blow:
Disconnect the device or equipment immediately.
1.
Find the source of the problem, and repair it.
2.
Install a new 15-amp fuse. The fuse can be found on the end
3.
of the plug on the inverter.
Do not over-tighten the fuse cap; finger-tight is sufficient.
4.
ATTENTION:
Do not install a fuse higher than 15-amp, as this may
damage the inverter. Make sure to correct the cause of the blown
fuse before using the inverter again.