8
INSTALLATION
INSTALLATION
FIGURE 6
- RUBBER FEET ASSEMBLY
1. Assembly:
For this compressor: after removing it from its package, assemble (when it does not came fixed)
the rubber feet (Figure 6).
2. Location:
2.1 Compressor's installation:
3. Position:
4. Quality of compressed air:
5. Electrical connection:
5.1
Install the compressor in a covered, well ventilated area, free of dust, gases, toxic gases,
humidity or any other kind of pollution. The ambient temperature recommended during work is:
minimum of 5 C (41 F) and maximum of 40 C (104 F). In order to avoid damage to the compressor,
operate it on a level foundation.
When this compressor model is coupled to a compressed air
network, the connection must be made by a hose or expandable joints so that the charges, thermal
expansion, piping's weight, mechanical and thermal shocks or obstructions are not transmitted to
the tank. The tank may be damaged if these warnings are not observed.
Keep a minimum distance of 800 mm (32 inch) from any
obstacle, to allow good
ventilation during operation and to make maintenance easier.
For services in which the air must be free of dust particles, the
installation of special air filters. Please contact us at
for information.
Look for a specialized technician to evaluate the electrical supply and to select the adequate
protection and input devices. (Installation conform Figure 7)
0
0
0
0
5.2
5.3
F
T
ollow the local technical standards on low voltage electric installations.
he electric input cables must be in accordance to the motor's power, voltage and electrical
energy source distance (See Table 2, page 9- for orientation).
e electric wire with plug as shown in Figure 5: 3 pins (single-
phase). Make sure the outlet has the same configuration as the
plug. Neither adaptors nor a direct conn
Th
ection from the power
cable to the switch must be used.
5.4
F1
Ground
Tension
Supplies
PLUG 2P+GR
OR WIRE
Customer's responsibility
Phase
N
Neutral
P
M
1~
FIGURE 7 - ELECTRIC DIAGRAM
Electric motor
Pressure switch
Fuse type "D" or
"NH"(see Table 2 - page 9)
F1
P
M
FIGURE 5
GROUNDED
OUTLET
GROUNDING
PIN
OILESS AIR COMPRESSOR
Содержание CSA 7.8/15-SIDESTACK
Страница 1: ...OWNER S MANUAL OILESS AIR COMPRESSOR ...