GB
64
Parameter setting for MC 1500
Precise setting of the parameters only
by computer control of the MC 1500.
The MC 1500 controller’s keypad only
allows rough visible adjustment.
* The values indicated with * can only
be changed via computer.
➔
The values indicated with
➔
are
derivative values that cannot be
directly set.
Properties
Values
Tested in
accordance with
Light
intensity setting
brightness ranges
MC 1500:
1 = No LED lit up
2 = One green LED
3 = Two green LEDs
4 = Two green and
one yellow LED
5 = Two green, one
yellow and one
red LED
%
0 – 100
0 – 1
2 – 32
33 – 59
60 – 82
83 – 100
Base
setting
32%
Rotation mode
Angle of single
rotation step
illumination time
of each step*
➔
Rotation
speed*
ms
45°
2 – 500
➔
0.25–62.5 rps
125 ms
➔
1 rps
Strobe mode
Strobe cycle
duration
➔
Strobe frequency
Strobe pulse duration
Strobe
intensity*
µs
µs
%
100 – 65 000,
(full intensity from on 500 µs)
➔
Strobe frequency
15 – 2000 Hz (10 000 Hz)
80 – 65 000
0 – 100 without overdrive
0 – 300, if overdrive
conditions fulfilled
(see Section 8.6)
deaktiviert
40 000
➔
20 Hz
2500
300
Trigger mode
Light pulse duration
Light pulse
intensity*
Delay time*
µs
ms
80 – 65 000
0 – 100 without overdrive
0v300, if „pulse duration
< 10 000 µs“
0 – 16 000
(only limited settings pos-
sible via controller keypad)
deaktiviert
2500
300
10 00
Flash mode
Flash duration
µs
80 – 65 000
2500
Содержание VisiLED MC 1000
Страница 1: ...VisiLED Series Gebrauchsanweisung DE GB FR ...
Страница 2: ......
Страница 4: ......
Страница 9: ...153 MC 1500 A B 110 110 40 A B RS232 21V dc I O 153 40 DE 7 2 Controller 2 1 MC 1500 in mm ...
Страница 41: ...GB 39 153 MC 1500 A B 110 110 40 A B RS232 21V dc I O 153 40 2 Controller 2 1 MC 1500 in mm ...
Страница 102: ...100 Notes ...
Страница 103: ...101 ...