Equalizer Key Points
Using the equalizer has limitations, which should be understood before using it.
First, the equalizer relies on the CLO, which is averaged over many milliseconds to maintain a steady
control loop. Because of this, the equalizer may not perform well if used with strobe modes.
Second, the equalizer needs enough room in the driver to increase or decrease the current with time to
maintain the light output. This means if the light is already at 100%, the equalizer cannot increase the
current if light output decreases.
Third, because the light output will change significantly when the unit is first turned on, the user should
give sufficient time for the light output to stabilize at a satisfactory level before engaging the equalizer.
When the equalizer is enabled for the first time, it will set the current light output as its target. This can
be manually changed later with the “Target Light Output” controls if needed.
Once the settings are stored, upon future power ups, the unit will return to the set “Target Light
Output” value.
The final control in this section is to a time delay. This is a delay, in seconds, after the unit “Output
Power” is enabled, before the equalizer will start controlling the output current.
Содержание ColdVision
Страница 36: ...D20980 022 Rev C CV LS User Manual Page 36 LED LED UV UV LED RMA 91...
Страница 38: ...D20980 022 Rev C CV LS User Manual Page 38 1 SCHOTT SCHOTT machine vision moritex com...
Страница 42: ...D20980 022 Rev C CV LS User Manual Page 42 LED LED UV UV LED Return Material Authorization RMA 91...
Страница 44: ...D20980 022 Rev C CV LS User Manual Page 44 SCHOTT SCHOTT machine vision moritex com...