CV-LS Dashboard
D20980.022 Rev C
CV-LS User Manual
Page 62
Continuous Strobe
In Continuous Strobe mode, the unit will generate a trigger source from its internal clock. This allows the
user to set up a continuous strobe train to stop motion in machine vision applications.
Note:
Strobe intensity is set by the analog dimming level under the “LED Channel Settings” section.
Figure 10: Continuous Strobe (Left: Dashboard, Right: Web Interface)
Control Name
Description
Continuous Strobe
Options: Enable, Disable
When this option, along with the Output Power, is enabled, the LED will
strobe at the settings listed below.
Channel Operation
Options: Single, Quad
When in Single mode, all four channels strobe with the settings of Channel 1.
Quad mode shows settings for each channel individually.
Frequency Slider and
Numeric Up Down
Range: 6 – 20,000 Hz
Frequency of the strobe trigger.
Channels
Options: 1, 2, 3, 4, All
When in Quad mode, all options are displayed to allow the user to show
different channel settings. If ALL is selected, then all four channel settings are
displayed at once.
Note:
The following settings, denoted by
Ch X,
are the same for all four
channels.
Ch X Duty Cycle (%)
Range: 0-100.0
Percent of the waveform that is active.
Ch X Phase Shift (%)
Range: 0-100.0
Percent of the waveform the strobe will wait before becoming active.
Ch X Waveform
Options: Active High, Active Low
Sets the state of the LED during the Active part of the waveform. High = LED
On, Low = LED Off.
Содержание ColdVision
Страница 36: ...D20980 022 Rev C CV LS User Manual Page 36 LED LED UV UV LED RMA 91...
Страница 38: ...D20980 022 Rev C CV LS User Manual Page 38 1 SCHOTT SCHOTT machine vision moritex com...
Страница 42: ...D20980 022 Rev C CV LS User Manual Page 42 LED LED UV UV LED Return Material Authorization RMA 91...
Страница 44: ...D20980 022 Rev C CV LS User Manual Page 44 SCHOTT SCHOTT machine vision moritex com...