CV-LS Dashboard
D20980.022 Rev C
CV-LS User Manual
Page 61
Control Name
Description
Output Power
Options: On, Off
This button controls the LED. This must be set to ON before the LED can turn
on. When control is set to ON, the LED can still be off by using the shutdown
pin on the Multiport connector.
Note:
This setting is also controlled by the button on the front panel of the
unit.
Note:
If this setting is ON, but the LED is not coming on, check the individual
channel settings.
Output Power Slider
and Numeric Up Down
Range: 0-100.0
This sets the output power of the LED.
Note:
This setting is also controlled by the knob on the front panel of the unit.
Channels
Options: 1, 2, 3, 4, All
When in Quad mode, all options are displayed to allow the user to show
different channel settings. If ALL is selected, then all four channel settings are
displayed at once.
Note:
The following settings, denoted by
Ch X,
are the same for all four
channels.
Ch X Power Limit
Options: On, Off
This button controls the individual channel. This allows the user to selectively
turn off an individual channel, even if the Output Power is on.
Ch X Power Limit Slider
and Numeric Up Down
Range: 0-100.0
This sets the power limit of an individual channel. This scaler is applied to the
main power setting to calculate the actual power of a channel.
Note:
This setting can be lowered to limit the total output power. This is
useful in situations where user control of the front knob is required, but a
maximum light output is needed at less than 100%.
Note:
The default setting on single channel units is 75%, to limit temperature
of the LED while at minimum fan speed. This can be increased by changing to
Industrial or Heavy Industrial mode, as outlined in the Unit Operating Modes
section on page 45.
Ch X Shutdown Pin
Options: Active Low, Active High
This setting controls when the unit will be in shutdown mode based off the
input from the multiport. The default is Active Low, so if the Multiport
Shutdown Pin is pulled to GND (either driven or with a contact closure), the
LED channel will not turn on. In a single channel device, a low signal on
Channel 1 will turn off the light completely.
Содержание ColdVision
Страница 36: ...D20980 022 Rev C CV LS User Manual Page 36 LED LED UV UV LED RMA 91...
Страница 38: ...D20980 022 Rev C CV LS User Manual Page 38 1 SCHOTT SCHOTT machine vision moritex com...
Страница 42: ...D20980 022 Rev C CV LS User Manual Page 42 LED LED UV UV LED Return Material Authorization RMA 91...
Страница 44: ...D20980 022 Rev C CV LS User Manual Page 44 SCHOTT SCHOTT machine vision moritex com...