background image

LIABILITIES 

Any warranty implied under State Law shall be limited to one year from original delivery to original purchaser. Specifically 

excluded from the manufacturer liability is damage resulting from acts of any deity, malicious mischief, vandalism, riots, 
wars, improper installation or neglect in the operation or maintenance of the unit or misunderstanding of the properties of 
the unit. Under no circumstances shall the manufacturer be obligated for consequential or other damages of any kind or 
description, losses or expenses in connection with or by reason of the use of, or inability to use this unit for any reason. The 
stated warranty provides the purchaser with specific legal rights, and there may be additional rights which vary from State to 
State. Some States for example, do no allow exclusion of consequential damage. 

SERVICE POLICY 

Any service required for any reason must be performed by the manufacturer or an authorized service representative. All 

service out-side the warranty will be performed upon the purchaser’s request according to normal service charges in effect 
at the time. To return any item, an RMA# (Return Materials Authorization) from the manufacturer must be obtained. This 
number must be affixed to the shipping label in plain sight. All shipping must be prepaid. The manufacturer guarantees all 
repairs will be completed within two weeks. The manufacturer will return ship all units prepaid using carrier of choice. All 
expedited shipping charges will be the responsibility of the purchaser. 

 

D 20500.020 Rev. L – Jan. 2010      DCN # 14010

Содержание ACE A20500

Страница 1: ...z 60Hz SOLID STATE RHEOSTAT A20500 EKE Lamp A20500 1 EJA Lamp A20500 2 DDL Lamp A20510 EKE Lamp A20510 1 EJA Lamp A20510 2 DDL Lamp SOLID STATE RHEOSTAT AND IRIS DIAPHRAGM A20520 EKE Lamp A20520 1 EJA Lamp A20520 2 DDL Lamp A20530 EKE Lamp A20530 1 EJA Lamp A20530 2 DDL Lamp 122 Charlton Street Southbridge MA 01550 1960 ...

Страница 2: ...Phone 508 765 9744 Fax 508 765 1299 Email lightingimaging us schott com www us schott com lightingimaging ...

Страница 3: ...igh output fan provides maximum airflow resulting in extremely cool operation We suggest you read this manual carefully to become familiar with all the light source features and how they work MAINTENANCE Although your light source is designed to be maintenance free it does contain sensitive electronic parts TREAT IT WITH CARE TO ASSURE BEST PERFORMANCE The original packaging should be used for pro...

Страница 4: ...cause burns Operators are advised to allow the unit to cool before opening or relamping Modulamp assembly ...

Страница 5: ...eptacle and tighten the fiber optic positioning thumbscrew Adjust the intensity of the lamp using the control knob To turn the unit off turn the intensity control knob to the OFF position OPERATIONS 1 Mettre l interrupteur sur position off 2 Connecter le cordon d alimentation à la source et le brancher au secteur 3 Vérifier que la vis sur la face avant du module lampe soit fermement visée 4 Insére...

Страница 6: ...iefern 4 Feststellschraube des Lampeneinschubes fest anziehen 5 Kompatibles Faserbündel in den Faserbündeladapter der Lichtquelle einführen 6 Feststellschraube des Faserbündeladapters anziehen 7 Netzschalter in ON Stellung bringen 8 Intensität der Lampe mit Kontrollpotentiometer auf gewünschten Wert einstellen 9 Zum Abschalten der Lichtquelle den Netzschalter in OFF Stellung bringen FUNZIONAMENTO ...

Страница 7: ...S MAY AFFECT THE LAMP OUTPUT Push the ceramic socket on the two lamp pins until flush with the reflector TO REPLACE THE MODULAMP ASSEMBLY Slide the connector into the mating receptacle until the release tab clicks into place Place the Modulamp assembly into the recess with the two bottom ears riding over the bottom edge of the recess first Slide the Modulamp assembly into place and depress the cap...

Страница 8: ...settings may be changed by moving the lamp holder into the correct position Consult the factory for correct lamp locations ...

Страница 9: ...l enchufe cerámico 10 Deslizar la Modulámpara en las orejas del origen de luz por encima del borde del fondo al principio 11 Apretar el tornillo LAMPENWECHSEL 1 Nettzschalter in OFF Stellung bringen 2 Faserbündeladapter herausziehen 3 Lampe abkühlen lassen 4 Feststellschraube des Lampenienschubes so lange lösen bis die Einschubkassette herausspringt 5 An der Oberseite des Lampeneinschubes ziehen u...

Страница 10: ...a del cavo 6 Abbassare il dispositivo di sgancio del portalampada per rimuovere la lampadina 7 Delicatamente staccare il portalampada in ceramica 8 Inserire la nuova lampadina nel portalampada NON toccare il bulbo o l interno del riflettore 9 Spingere la lampadina nel portalampada in ceramica fino a livello di base ...

Страница 11: ...rriscaldate SAFETY INSTRUCTIONS 1 READ UNDERSTAND AND FOLLOW ALL INSTRUCTIONS in this manual 2 KEEP all safety and operating instructions for future reference 3 HEED ALL WARNINGS on the unit and in this manual 4 DO NOT USE this unit near water or in any area with excessive moisture 5 MOUNT on surface platform or wall ONLY as recommended by the manufacturer 6 DO NOT BLOCK ventilation openings in th...

Страница 12: ...is no light check the following in sequence 1 Turn the Intensity Control knob to 100 2 Change the bulb 3 Examine lamp socket for damage Check continuity of wiring If contacts are carburized or the ceramic base is cracked or the wiring is frayed replace socket 4 Make sure that the two pin modular connector is properly engaged in the locking position see lamp replacement section Check contacts for p...

Страница 13: ... 50Hz Models A20510 A20530 Output 21VAC Power Consumption 190 Watts nominal Lamp Types Tungsten Halogen 150 Watt 21 Volt EJA EKE 150 Watt 20 Volt DDL CSA to UL 1571 Improvements may result in specification or feature changes without notice PARTS LIST EJA Lamp A08110 Rheostat Control Knob H09033 100 EKE Lamp A08120 Iris Control Knob H09050 045 DDL Lamp A08130 Fuse 10 pkg 115 V units A08126 Lamp Soc...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ...fic legal rights and there may be additional rights which vary from State to State Some States for example do no allow exclusion of consequential damage SERVICE POLICY Any service required for any reason must be performed by the manufacturer or an authorized service representative All service out side the warranty will be performed upon the purchaser s request according to normal service charges i...

Отзывы: