background image

be pinched, severed or walked on. 

11

DO NOT DEFEAT THE PURPOSE OF THE FUSE. Replace only with fuse type described 
in the operating instructions or as marked on the unit. 

12

USE ONLY STANDARD GLASS TYPE CLEANERS. Do not use solvents, cleansers or 
petroleum distillates. UNPLUG all cords before cleaning. 

13

NEVER SPILL LIQUID ON THE UNIT OR PUSH OBJECTS INTO VENTILATION 
OPENINGS. You may short out parts, resulting in risk of fire or electric shock. 

14

DISCONNECT POWER CORD from outlet when unit will be left unused for a long period of 
time. 

15

DO NOT OPEN THIS UNIT. There are no user serviceable parts inside. 

16

The unit should be serviced ONLY by SCHOTT authorized service personnel if it does not 
operate normally or exhibits any marked change in performance; or if the power cord or 
enclosure has been damaged; or if objects or moisture have entered the unit. 

17

DO NOT SERVICE the unit beyond that described in this manual. All other servicing should 
be referred to qualified service personnel. 

TROUBLESHOOTING 

If the fan operates, but there is no light, check the following in sequence. 

1

Turn the Intensity Control knob to 100. 

2

Change the bulb. 

3

Examine lamp socket for damage. Check continuity of wiring. If contacts are carburized or 
the ceramic base is cracked or the wiring is frayed, replace socket. 

4

Make sure that the two pin modular connector is properly engaged in the locking position 
(see lamp replacement section). Check contacts for proper operation. 

If neither the lamp nor the fan operates, check the following in sequence. 

1

Make sure the power cord is inserted completely into the IEC connector on the rear panel 
and also into the correct power source. 

2

Check power cord for damage. 

3

Check fuse. Remove the power cord. Slide fuse drawer out and remove inner fuse. Check 
for continuity. Replace with spare fuse if blown. 

REPLACE ONLY WITH FUSE TYPE 

DESCRIBED ON REAR PANEL.

Replace or reorder spare fuse. 

4

If the unit feels warm, check for any obstruction to the air intakes or exhaust area. This light 
source has an automatic reset, thermal cut-out device for safety protection. Let the unit 
cool down for 10 minutes and turn it back on. 

If the light source still doesn’t operate

, refer to qualified SCHOTT authorized service 

personnel. 

DO NOT ATTEMPT TO REPAIR THE LIGHT SOURCE!

Содержание ACE A20500

Страница 1: ...z 60Hz SOLID STATE RHEOSTAT A20500 EKE Lamp A20500 1 EJA Lamp A20500 2 DDL Lamp A20510 EKE Lamp A20510 1 EJA Lamp A20510 2 DDL Lamp SOLID STATE RHEOSTAT AND IRIS DIAPHRAGM A20520 EKE Lamp A20520 1 EJA Lamp A20520 2 DDL Lamp A20530 EKE Lamp A20530 1 EJA Lamp A20530 2 DDL Lamp 122 Charlton Street Southbridge MA 01550 1960 ...

Страница 2: ...Phone 508 765 9744 Fax 508 765 1299 Email lightingimaging us schott com www us schott com lightingimaging ...

Страница 3: ...igh output fan provides maximum airflow resulting in extremely cool operation We suggest you read this manual carefully to become familiar with all the light source features and how they work MAINTENANCE Although your light source is designed to be maintenance free it does contain sensitive electronic parts TREAT IT WITH CARE TO ASSURE BEST PERFORMANCE The original packaging should be used for pro...

Страница 4: ...cause burns Operators are advised to allow the unit to cool before opening or relamping Modulamp assembly ...

Страница 5: ...eptacle and tighten the fiber optic positioning thumbscrew Adjust the intensity of the lamp using the control knob To turn the unit off turn the intensity control knob to the OFF position OPERATIONS 1 Mettre l interrupteur sur position off 2 Connecter le cordon d alimentation à la source et le brancher au secteur 3 Vérifier que la vis sur la face avant du module lampe soit fermement visée 4 Insére...

Страница 6: ...iefern 4 Feststellschraube des Lampeneinschubes fest anziehen 5 Kompatibles Faserbündel in den Faserbündeladapter der Lichtquelle einführen 6 Feststellschraube des Faserbündeladapters anziehen 7 Netzschalter in ON Stellung bringen 8 Intensität der Lampe mit Kontrollpotentiometer auf gewünschten Wert einstellen 9 Zum Abschalten der Lichtquelle den Netzschalter in OFF Stellung bringen FUNZIONAMENTO ...

Страница 7: ...S MAY AFFECT THE LAMP OUTPUT Push the ceramic socket on the two lamp pins until flush with the reflector TO REPLACE THE MODULAMP ASSEMBLY Slide the connector into the mating receptacle until the release tab clicks into place Place the Modulamp assembly into the recess with the two bottom ears riding over the bottom edge of the recess first Slide the Modulamp assembly into place and depress the cap...

Страница 8: ...settings may be changed by moving the lamp holder into the correct position Consult the factory for correct lamp locations ...

Страница 9: ...l enchufe cerámico 10 Deslizar la Modulámpara en las orejas del origen de luz por encima del borde del fondo al principio 11 Apretar el tornillo LAMPENWECHSEL 1 Nettzschalter in OFF Stellung bringen 2 Faserbündeladapter herausziehen 3 Lampe abkühlen lassen 4 Feststellschraube des Lampenienschubes so lange lösen bis die Einschubkassette herausspringt 5 An der Oberseite des Lampeneinschubes ziehen u...

Страница 10: ...a del cavo 6 Abbassare il dispositivo di sgancio del portalampada per rimuovere la lampadina 7 Delicatamente staccare il portalampada in ceramica 8 Inserire la nuova lampadina nel portalampada NON toccare il bulbo o l interno del riflettore 9 Spingere la lampadina nel portalampada in ceramica fino a livello di base ...

Страница 11: ...rriscaldate SAFETY INSTRUCTIONS 1 READ UNDERSTAND AND FOLLOW ALL INSTRUCTIONS in this manual 2 KEEP all safety and operating instructions for future reference 3 HEED ALL WARNINGS on the unit and in this manual 4 DO NOT USE this unit near water or in any area with excessive moisture 5 MOUNT on surface platform or wall ONLY as recommended by the manufacturer 6 DO NOT BLOCK ventilation openings in th...

Страница 12: ...is no light check the following in sequence 1 Turn the Intensity Control knob to 100 2 Change the bulb 3 Examine lamp socket for damage Check continuity of wiring If contacts are carburized or the ceramic base is cracked or the wiring is frayed replace socket 4 Make sure that the two pin modular connector is properly engaged in the locking position see lamp replacement section Check contacts for p...

Страница 13: ... 50Hz Models A20510 A20530 Output 21VAC Power Consumption 190 Watts nominal Lamp Types Tungsten Halogen 150 Watt 21 Volt EJA EKE 150 Watt 20 Volt DDL CSA to UL 1571 Improvements may result in specification or feature changes without notice PARTS LIST EJA Lamp A08110 Rheostat Control Knob H09033 100 EKE Lamp A08120 Iris Control Knob H09050 045 DDL Lamp A08130 Fuse 10 pkg 115 V units A08126 Lamp Soc...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ...fic legal rights and there may be additional rights which vary from State to State Some States for example do no allow exclusion of consequential damage SERVICE POLICY Any service required for any reason must be performed by the manufacturer or an authorized service representative All service out side the warranty will be performed upon the purchaser s request according to normal service charges i...

Отзывы: