Scholtès UK
© 2010 Reg. Office: Peterborough PE2 9JB Registered in London: 106725
Service
Information
38 cm
GAS HOBS
Models
Comm.
Covered
Code
Single RingPMG41DCDRSF
57506
2 RingPMG42SF
57507
5413143 Issue 1 Oct. 2010
Страница 1: ...s UK 2010 Reg Office Peterborough PE2 9JB Registered in London 106725 Service Information 38 cm GAS HOBS Models Comm Covered Code Single Ring PMG41DCDRSF 57506 2 Ring PMG42SF 57507 5413143 Issue 1 Oc...
Страница 2: ...th your appliance 5 Genuine Scholt s UK spares should always be used when repairing Scholt s UK products For UK customers the fitting of non genuine spares could affect your rights under the product l...
Страница 3: ...PMG42SF 57507 Stainless Steel TECHNICAL DATA GENERAL LPG Conversion Kits are available C00090735 model PMG41 C00089138 model PMG42 COUNTRY OF ORIGIN Italy OVERALL DIMENSIONS Height 54 mm PMG41 47 mm P...
Страница 4: ...l power kW H s By pass 1 100 mm Injector 1 100 mm Flow g h Injector 1 100 mm Flow l h Nomin Reduc G30 G31 G20 D Triple Ring 130 3 25 1 3 57 91 236 232 124 309 A Auxiliary 55 1 00 0 4 30 50 73 71 71 95...
Страница 5: ...ndition where it could be connected to the electricity supply To help the environment Local Authority instructions should be followed for the disposal of the product Disposal of Old Electrical Applian...
Страница 6: ...dance with the current edition of the above regulations It is in your interest and that of safety to ensure compliance with the law In the UK Gas Safe CORGI in Northern Ireland registered installers w...
Страница 7: ...lt s Built In Ovens The hob should be checked to ensure that the voltage corresponds with the voltage supply this is stated on the rating plate which is situated on the base panel These hobs are desig...
Страница 8: ...the hob from the carton Remove the bag containing the sealing tape fixing brackets and screws Make sure that the seal adheres properly to the bottom part of the frame of the hob The seal must fit pro...
Страница 9: ...t correspond with the coloured marking identifying the terminals in the plug if this is the case proceed as follows The wire which is coloured BLUE must be connected to the terminal which is marked wi...
Страница 10: ...most appropriate burner to cook with CONTROL KNOBS for the gas burners adjust the power and size of the flame IGNITION for the gas burner enables a specific burner to be lit automatically SAFETY DEVIC...
Страница 11: ...he hob top d Remove the 2 screws that secure the 2 control taps to the hob top 1 screw per tap e Lift the hob top clear f Reassemble in reverse order 2 TO ACCESS THE CONTROLS a Disconnect the hob from...
Страница 12: ...ps noting that the Blue leads and microswitches are still connected e Remove the 2 screws securing the brackets on the gas rail to the control taps Remove the control tap assemblies from the gas rail...
Страница 13: ...f 13 Service Manual UK English WIRING DIAGRAM 66 22 L N 22 Tf Tp 66 66 230V 50Hz 15 Transformer Spark Generator Terminal Block Microswitch 22 Brown 66 Light Blue 15 Yellow Green 5413143wd pdf PMG41 PM...