Appendix
9.3
Technical specifications
Further technical data (
→
data sheet).
9.3.1
Ambient conditions
Operation under any other ambient conditions should be
agreed with the manufacturer.
Relative humidity [%]
Tempera-
ture [°C]
Long-term
Short-term
Installation
height
above sea
level [m]
–20 to +40
1)
≤
85
≤
100
≤
1000
Tab. 9
Ambient conditions
1) material-dependent
9.3.2
Total pressure
Total pressure = system pr pressure build-up in
the pump
Max. permissible total pressure (p
t
) = 6 bar
9.3.3
Installation dimensions
The end of the motor shaft and the inner surface of the external
magnet (19) must be flush:
A
19
Fig. 9
Installation dimension
A End of motor shaft and external magnet (19)
9.3.4
Tightening torques of casing screws
Comply with the following tightening torques and use a torque
wrench:
SMP size ...
Tightening torque [Nm]
130
3
150
3
170
5
Tab. 10
Tightening torques of casing screws
9.3.5
Pump housing fill volume
SMP size ...
Fill volume [l]
130
5.7
150
5.7
170
8.0
Tab. 11
Pump housing fill volume
9.3.6
Suction head after 180 s
SMP size ...
Motor power
rating [kw]
Max. permissible
suction head [m]
130
0.37
4.5
150
0.75
5.5
170
1.5
6.5
Tab. 12
Suction head
9.3.7
Cleaning agents
•
Strongly alkaline soap solution
•
Steam jet (only for individual parts)
30
SMP
11335/0320