7.2  Door gap calculation

Calculation of the door gap depending on the opening angle,  
door width and overlapping

β

10°

C

D

100

5.2

7.0

8.7

10.4

12.2

13.9

15.6

17.4

150

7.8

10.5

13.1

15.7

18.3

20.9

23.5

26.0

200

10.5

13.9

17.4

20.9

24.4

27.8

31.3

34.7

250

13.1

17.4

21.8

26.1

30.5

34.8

39.1

43.3

300

15.7

20.9

26.1

31.3

36.5

41.7

46.9

52.1

350

18.3

24.4

30.5

36.6

42.6

48.7

54.7

60.7

400

20.9

27.9

34.8

41.8

48.7

55.6

62.5

69.4

450

23.5

31.4

39.2

47.0

54.8

62.6

70.4

78.1

500

26.2

34.9

43.6

52.2

60.9

69.6

78.2

86.8

550

28.8

38.3

47.9

57.5

67.0

76.5

86.0

95.5

600

31.4

41.8

52.3

62.7

73.1

83.5

93.8

104.1

650

34.0

45.3

56.6

67.9

79.2

90.4

101.6

112.8

700

36.6

48.8

61.0

73.1

85.3

97.4

109.4

121.5

750

39.2

52.3

65.3

78.4

91.4

104.3

117.3

130.2

800

41.8

55.8

69.7

83.6

97.4

111.3

125.1

138.8

850

44.5

59.3

74.0

88.8

103.5

118.2

132.9

147.5

900

47.1

62.7

78.4

94.0

109.6

125.2

140.7

156.2

950

49.7

66.2

82.8

99.3

115.7

132.1

148.5

164.9

1,000

52.3

69.7

87.1

104.5

121.8

139.1

156.4

173.6

1,050

54.9

73.2

91.5

109.7

127.9

146.1

164.2

182.2

1,100

57.5

76.7

95.8

114.9

134.0

153.0

172.0

190.9

1,150

60.2

80.2

100.2

120.1

140.1

160.0

179.8

199.6

1,200

62.8

83.7

104.5

125.4

146.2

166.9

187.6

208.3

1,250

65.4

87.2

108.9

130.6

152.3

173.9

195.4

217.0

1,300

68.0

90.6

113.2

135.8

158.4

180.8

203.3

225.6

1,350

70.6

94.1

117.6

141.0

164.4

187.8

211.1

234.3

1,400

73.2

97.6

122.0

146.3

170.5

194.7

218.9

243.0

1,450

75.8

101.1

126.3

151.5

176.6

201.7

226.7

251.7

1,500

78.5

104.6

130.7

156.7

182.7

208.7

234.5

260.3

β = Door opening angle

C = Door width in mm
D is the door gap in mm with an overlap at B = 0 mm.
B is the thickness of the door

The actual door gap "D1" is calculated using door gap "D" calculated by 
means of the table above minus the overlapping "B" of door and frame:
D1 = D – B

C

β

D1

D

B

Example: 

A door made of 40 mm aluminium profile with a length of 950 mm 
should be secured with a TESK. The safety contact of the TESK opens 
to 3° when new according to the technical safety sheet (10° at the end 
of its service life). The table above shows the door gap when new at ap-
prox. 49.7 mm. The real door gap can be calculated with the following 
equation D1 = D – B; (49.7 – 40 = 9.7); D1 = 9.7 mm. At the end of the 
service life the door gap is approx. 164.9 mm and the real door gap is 
(164.9 – 40 = 124.9); D1 = 124.9 mm.

7.3  Load specifications

Determining the permissible forces as a function of door size and number of hinges.

Doors with one hinge

Force [N]

B [mm]

100

200

300

400

500

H [mm]

 up to 200

200

150

100

70

50

 up to 300

200

150

not recommen-

ded

B

F

H/2

H/2

H

The hinge should be placed in the middle with doors that only 
have one hinge.

Содержание TESK- 02 Series

Страница 1: ...nce with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulation...

Страница 2: ...n which the hazardous condition is terminated without delay e g run on movements when the safety guard is opened The user must evaluate and design the safety chain in accordance with the relevant standards and on the required safety level The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data Standards IEC...

Страница 3: ...r assembly and adjustment Fig 3 A A Fig 3 Legend A Drill and pin in this area The hinge safety switch must not be used as an end stop Any mounting position The mounting position however is chosen so that the components are preferably fitted in the upper part of the safety guard to avoid the ingress of dirt and soiling as well as damage to the components In case of painting activities the component...

Страница 4: ...nce of the switch with the safety technical requirements of the application must be checked See Section 7 2 Door gap calculation 4 After the switching angle has been set and checked the blanking plug for the adjustment opening located at the rear of the adjustment tool must be inserted in the adjustment opening 1 and torn down by making lateral movements 2 with the tool Fig 7 1 2 Fig 6 Fig 7 After...

Страница 5: ...losed TESK 22L TESK 13L WH 11 VT 23 12 BK 24 RD BN 31 32 BU GY 43 44 PK PE GN YE WH 11 VT 23 12 BK 24 RD BN 31 32 BU GY 41 42 PK PE GN YE TESK 12L TESK 02L WH 11 VT 23 12 BK 24 RD BN 31 32 BU PE GN YE BN 21 22 BU 12 BK WH 11 PE GN YE TESK 11L WH 11 BN 23 12 BK 24 BU PE GN YE TESK 22ST TESK 13ST 11 23 12 24 31 32 1 2 3 4 5 6 7 8 43 44 5 8 4 3 2 1 7 6 11 23 12 24 31 32 41 42 1 2 3 4 5 6 7 8 5 8 4 3 ...

Страница 6: ...or IP67 M12 5 pole 5 x 0 25 mm 1 BN 1 BN WH 2 WH 2 WH BN Cable length Part number 3 BU 3 BU GN 5 0 m 15 0 m 101209949 101209948 4 BK 4 BK YE 5 GY 5 GY GY Connector plug ST2 M12 8 pole 5 8 4 3 2 1 7 6 Pin configuration of the connector Colour code or conductor numbering of the below mentioned Schmersal connectors possible colour code of other commercially available connectors to EN 60947 5 2 2007 D...

Страница 7: ...4 146 2 166 9 187 6 208 3 1 250 65 4 87 2 108 9 130 6 152 3 173 9 195 4 217 0 1 300 68 0 90 6 113 2 135 8 158 4 180 8 203 3 225 6 1 350 70 6 94 1 117 6 141 0 164 4 187 8 211 1 234 3 1 400 73 2 97 6 122 0 146 3 170 5 194 7 218 9 243 0 1 450 75 8 101 1 126 3 151 5 176 6 201 7 226 7 251 7 1 500 78 5 104 6 130 7 156 7 182 7 208 7 234 5 260 3 β Door opening angle C Door width in mm D is the door gap in...

Страница 8: ... 750 750 700 600 550 550 500 500 450 400 350 300 up to 2600 750 700 600 500 450 450 400 400 400 400 350 300 B D C F 0 5 5 x H H 8 H 5 H 8 H 5 H 5 0 6 x H H C Use of one hinge switch and an additional hinge D Use of one hinge switch and two additional hinges With larger doors the have three hinges make sure the two of the hinges are located in the upper third We recommend that the hinge switch is p...

Страница 9: ...e Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal November 27 2013 Authorised signature Philip Schmersal Managing Director EC Declaration of conformity Translation of the original Declaration of Conformity K A Schmersal GmbH Co KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30 42279 Wuppertal ...

Страница 10: ...o KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Отзывы: