7
TESK
Operating instructions
Hinge safety switch
EN
7.2 Door gap calculation
Calculation of the door gap depending on the opening angle,
door width and overlapping
β
3°
4°
5°
6°
7°
8°
9°
10°
C
D
100
5.2
7.0
8.7
10.4
12.2
13.9
15.6
17.4
150
7.8
10.5
13.1
15.7
18.3
20.9
23.5
26.0
200
10.5
13.9
17.4
20.9
24.4
27.8
31.3
34.7
250
13.1
17.4
21.8
26.1
30.5
34.8
39.1
43.3
300
15.7
20.9
26.1
31.3
36.5
41.7
46.9
52.1
350
18.3
24.4
30.5
36.6
42.6
48.7
54.7
60.7
400
20.9
27.9
34.8
41.8
48.7
55.6
62.5
69.4
450
23.5
31.4
39.2
47.0
54.8
62.6
70.4
78.1
500
26.2
34.9
43.6
52.2
60.9
69.6
78.2
86.8
550
28.8
38.3
47.9
57.5
67.0
76.5
86.0
95.5
600
31.4
41.8
52.3
62.7
73.1
83.5
93.8
104.1
650
34.0
45.3
56.6
67.9
79.2
90.4
101.6
112.8
700
36.6
48.8
61.0
73.1
85.3
97.4
109.4
121.5
750
39.2
52.3
65.3
78.4
91.4
104.3
117.3
130.2
800
41.8
55.8
69.7
83.6
97.4
111.3
125.1
138.8
850
44.5
59.3
74.0
88.8
103.5
118.2
132.9
147.5
900
47.1
62.7
78.4
94.0
109.6
125.2
140.7
156.2
950
49.7
66.2
82.8
99.3
115.7
132.1
148.5
164.9
1,000
52.3
69.7
87.1
104.5
121.8
139.1
156.4
173.6
1,050
54.9
73.2
91.5
109.7
127.9
146.1
164.2
182.2
1,100
57.5
76.7
95.8
114.9
134.0
153.0
172.0
190.9
1,150
60.2
80.2
100.2
120.1
140.1
160.0
179.8
199.6
1,200
62.8
83.7
104.5
125.4
146.2
166.9
187.6
208.3
1,250
65.4
87.2
108.9
130.6
152.3
173.9
195.4
217.0
1,300
68.0
90.6
113.2
135.8
158.4
180.8
203.3
225.6
1,350
70.6
94.1
117.6
141.0
164.4
187.8
211.1
234.3
1,400
73.2
97.6
122.0
146.3
170.5
194.7
218.9
243.0
1,450
75.8
101.1
126.3
151.5
176.6
201.7
226.7
251.7
1,500
78.5
104.6
130.7
156.7
182.7
208.7
234.5
260.3
β = Door opening angle
C = Door width in mm
D is the door gap in mm with an overlap at B = 0 mm.
B is the thickness of the door
The actual door gap "D1" is calculated using door gap "D" calculated by
means of the table above minus the overlapping "B" of door and frame:
D1 = D – B
C
β
D1
D
B
Example:
A door made of 40 mm aluminium profile with a length of 950 mm
should be secured with a TESK. The safety contact of the TESK opens
to 3° when new according to the technical safety sheet (10° at the end
of its service life). The table above shows the door gap when new at ap-
prox. 49.7 mm. The real door gap can be calculated with the following
equation D1 = D – B; (49.7 – 40 = 9.7); D1 = 9.7 mm. At the end of the
service life the door gap is approx. 164.9 mm and the real door gap is
(164.9 – 40 = 124.9); D1 = 124.9 mm.
7.3 Load specifications
Determining the permissible forces as a function of door size and number of hinges.
Doors with one hinge
Force [N]
B [mm]
100
200
300
400
500
H [mm]
up to 200
200
150
100
70
50
up to 300
200
150
not recommen-
ded
B
F
H/2
H/2
H
The hinge should be placed in the middle with doors that only