schmersal T 335 AS Скачать руководство пользователя страница 5

5

T 335 AS

T 336 AS

Operating instructions

Position switch with safety function

EN

6.  Diagnostic

6.1  LED indications

The LED's have the following meaning (to EN 50295):

LED yellow

Channel 1 / AS-i SaW-Bit 0,1

green/red LED  

(AS-i Duo LED):

AS-Interface supply voltage/ 

AS-Interface communication error 

or slave address = 0 or periphery error

LED yellow

Channel 2 / AS-i SaW-Bit 2,3

Channel 1

Channel 2

AS-iDuoLED

6.2  Read-out of the parameter port

The parameter port P0 to P3 of an AS-i slave can be read out through 

the control interface of the AS-i master (see component description) by 

means of the "Write parameter" instruction (with hexadecimal value F) 

This (non-safe) diagnostic information from the reflected parameters or 

the answer to a "Write parameter instruction" can be used by the user 

for diagnostic purposes or for the control programme

Table 3: diagnostic information (P0 … P3)

Parameter bit

Condition = 1

Condition = 0

0

Channel 2 activated

Channel 2 disabled

1

2

3

7.  Set-up and maintenance

7.1  Functional testing

The safety function of the safety components must be tested The 

following conditions must be previously checked and met:

1 Check the switch enclosure for damage

2 Check the free movement of the actuating element

3 Check the integrity of the cable entry and connections

7.2  Maintenance

We recommend a regular maintenance, including the following steps:

1 Check the free movement of the actuating element

2 Remove particles of dust and soiling

3 Check cable entry and connections

Damaged or defective components must be replaced.

8.  Disassembly and disposal

8.1  Disassembly

The safety switchgear must be disassembled in a de-energised 

condition only

8.2  Disposal

The safety switchgear must be disposed of in an appropriate manner in 

accordance with the national prescriptions and legislations

Содержание T 335 AS

Страница 1: ...functionality of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc...

Страница 2: ...yclically transmitted over the AS i network and monitored by the ASM safety monitor The component status can be evaluated through a PLC with AS Interface master The safety related functions are enabled by means of the AS i safety monitor The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level 2 4 Technical data Standards EN 60947 5...

Страница 3: ...60 66 5 7 3 30 16 5 76 M12x1 20 30 30 5 17 38 23 24 22 24 FK T 336 AS 9 5 Ø 5 3 60 66 5 30 7 3 M12x1 40 5 16 5 76 30 5 15 5 17 38 24 23 FK 24 Actuator heads T 335 336 AS Selection and dimensions refer to SCHMERSAL Main catalogue Safety Technology 3 3 Changing the switching function 4VH 4V7H 4V10H Position switches with 4V actuating head can be set so that they are switched either only clockwise on...

Страница 4: ...onfiguration 5 1 Programming the slave address The slave address is programmed through the M12 connector Any address from 1 to 31 can be set by means of the AS i bus master or a hand held programming device 5 2 Configuration of the safety monitor The safety switch can be configured in the ASIMON configuration software with the following monitoring devices refer to ASIMON manual Double channel depe...

Страница 5: ...purposes or for the control programme Table 3 diagnostic information P0 P3 Parameter bit Condition 1 Condition 0 0 Channel 2 activated Channel 2 disabled 1 2 3 7 Set up and maintenance 7 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Check the switch enclosure for damage 2 Check the free movement of the...

Страница 6: ... Type See ordering code Description of the component Positive break position switch for safety functions with integrated AS i Safety at Work Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards DIN EN 60947 5 1 2010 DIN EN ISO 13849 1 2016 IEC 61508 parts 1 7 2010 Person authorised for the compilation of the technical documentation...

Отзывы: