schmersal T 335 AS Скачать руководство пользователя страница 2

2

Operating instructions

Position switch with safety function

T 335 AS

T 336 AS

EN

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded The relevant requirements 

of the standard EN 1088 must be observed

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

T

 33

 

-AS

No. Option

Description

T

Slow action 

A

Actuator selection refer to main catalogue "Safety Technology"

5

Metal enclosure

6

Thermoplastic enclosure

ST

M12 x 1 connector

FK

Flat cable connection

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Machinery Directive is maintained

2.2  Special versions

For special versions, which are not listed in the order code below 21, 

these specifications apply accordingly, provided that they correspond to 

the standard version

2.3  Purpose

The safety switch is suitable for hinged or sliding guards, which need 

to be closed in order to provide for the necessary operational safety 

The combination of the safety switch and the AS-i ASM safety monitor 

provides a safe monitoring of the condition of the corresponding safety 

guard

The safety function consists in safely switching off the code 

transmission when the safety guard is opened and maintaining the safe 

switched off condition for as long as the safety guard is open

An AS-Interface Safety at Work component functions on the basis of 

an individual code generator (8 x 4 bit) This safety code is cyclically 

transmitted over the AS-i network and monitored by the ASM safety 

monitor

The component status can be evaluated through a PLC with AS-

Interface master The safety-related functions are enabled by means of 

the AS-i safety monitor

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level

2.4  Technical data

Standards:

 

EN 60947-5-1, EN 50295,  

EN ISO 13849-1, IEC 61508

Design:

 

fixings to EN 50041

Enclosure:

 

335: zinc die-cast, enamel finish  

336: glass-fibre reinforced thermo- 

plastic, self-extinguishing

Switching system:

 

Slow action, positive break NC contact 

A

Mechanical life:

 

≥ 1 million operations

Max switching frequency:

 5000/h

Max Actuating speed:

 

1 m/s

Response time:

 

< 100 ms

Termination:

 

335: connector M12, 5 pole, or FK  

336: connector M12, 4 pole, or FK

Electrical data - AS-Interface:

 

AS-i supply voltage:

 

180 … 316 VDC through AS-Interface,  

reverse polarity-proof (stabilised PELV units)

AS-I power consumption:

 

≤ 0.05 A

AS-i device insulation:

 

internal short-circuit proof

AS-I specification:

 

Version:

 

V 30

Profile:

 S-0BFF

IO-Code:

 0x0

ID-Code:

 0xB

ID-Code 1: 

0xF

ID-Code 2:

 0xF

AS-interface inputs:

 

Channel 1:

 

DI 0 / DI 1 = dynamic code transmission

Channel 2:

 

DI 2 / DI 3 = dynamic code transmission

AS-interface outputs:

 

DO 0 … DO 3:

 

no function

AS-Interface parameter port:

 

P0:

 

Channel 2 switched

P1 … P3:

 

no function

Input module address:

 0

preset to address 0, can be changed through  

AS-interface bus master or hand-held programming device

LED switching conditions display:

 

LED yellow:

 

Channel 1, SaW-Bit 01

LED green-red (AS-i Duo LED):

 

AS-Interface supply voltage /  

AS-Interface communication error /  

slave address = 0 or periphery error detected

LED yellow:

 

Channel 2, SaW-Bit 23

Ambient conditions:

 

Protection class:

 IP67

Ambient temperature:

 

−25 °C … +60 °C

Storage and transport temperature: 

 

–25 °C … +85 ºC

Relative humidity:

 

30 … 95%,  

no condensation, no icing

Resistance to vibration:

 

10 … 150 Hz (035 mm / 5 g)

Resistance to shock:

 

30 g / 11 ms

Protection rating:

 II 

x

 (only 336)

Overvoltage category:

 III

Degree of pollution:

 3

Rated impulse withstand voltage U

imp

:

 

800 V

Rated insulation voltage U

i

:

 

32 VDC

2.5  Safety classification

Standards:

 

EN ISO 13849-1, IEC 61508

PL:

 

up to 

Control category:

 

up to 1

PFH-value

114 x 10

-6

 / h up to max 100,000 switching cycles/year

SIL:

 

up to 1

Service life:

 

20 years

If a fault exclusion of a hazardous damage to the 1-channel  

mechanics is authorised and sufficient protection  

against tampering is ensured, suitable up to:

PL:

 

up to d

Control category:

 

up to 3

PFH-value:

 

101 x 10

-7

 /h up to max 100,000 switching cycles/year

SIL:

 

up to 2

Service life:

 

20 years

Содержание T 335 AS

Страница 1: ...functionality of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc...

Страница 2: ...yclically transmitted over the AS i network and monitored by the ASM safety monitor The component status can be evaluated through a PLC with AS Interface master The safety related functions are enabled by means of the AS i safety monitor The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level 2 4 Technical data Standards EN 60947 5...

Страница 3: ...60 66 5 7 3 30 16 5 76 M12x1 20 30 30 5 17 38 23 24 22 24 FK T 336 AS 9 5 Ø 5 3 60 66 5 30 7 3 M12x1 40 5 16 5 76 30 5 15 5 17 38 24 23 FK 24 Actuator heads T 335 336 AS Selection and dimensions refer to SCHMERSAL Main catalogue Safety Technology 3 3 Changing the switching function 4VH 4V7H 4V10H Position switches with 4V actuating head can be set so that they are switched either only clockwise on...

Страница 4: ...onfiguration 5 1 Programming the slave address The slave address is programmed through the M12 connector Any address from 1 to 31 can be set by means of the AS i bus master or a hand held programming device 5 2 Configuration of the safety monitor The safety switch can be configured in the ASIMON configuration software with the following monitoring devices refer to ASIMON manual Double channel depe...

Страница 5: ...purposes or for the control programme Table 3 diagnostic information P0 P3 Parameter bit Condition 1 Condition 0 0 Channel 2 activated Channel 2 disabled 1 2 3 7 Set up and maintenance 7 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Check the switch enclosure for damage 2 Check the free movement of the...

Страница 6: ... Type See ordering code Description of the component Positive break position switch for safety functions with integrated AS i Safety at Work Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards DIN EN 60947 5 1 2010 DIN EN ISO 13849 1 2016 IEC 61508 parts 1 7 2010 Person authorised for the compilation of the technical documentation...

Отзывы: