schmersal SRB402EM Скачать руководство пользователя страница 4

4

Operating instructions

Output expander module

SRB402EM

SRB402EM/CC

EN

6.  Set-up and maintenance

6.1  Functional testing

The function of the output expander module must be tested. The 

following conditions must be previously checked and met:

1. Correct fixing

2. Check the integrity of the cable entry and connections

3.  Check the output expander module's enclosure for damage.

6.2  Maintenance

A regular visual inspection and functional test, including the following 

steps, is recommended:

1. Check the correct fixing of the output expander module

2. Check the cable for damages

3. Check electrical function

The device has to be integrated into the periodic check-ups 

according to the Ordinance on Industrial Safety and Health, 

however at least 1 × year.

Damaged or defective components must be replaced.

7.  Disassembly and disposal

7.1  Disassembly

The output expander module must be disassembled in the de-

energised condition only. Push up the bottom of the enclosure and hang 

out slightly tilted forwards.

7.2  Disposal

The output expander module must be disposed of in an appropriate 

manner in accordance with the national prescriptions and legislations.

8.  Appendix

8.1  Wiring example

Single-channel control at terminal A1 of the SRB402EM expander 

module through a safety release of the basic module (Fig. 1)

•  The terminals X1 and X2 of the expander module must be connected 

to the feedback circuit or the single-switch circuit of the basic module.

Safety notice:

 the expander module must be wired in 

accordance with the wiring example. 

The safety function is 

only realised in conjunction with the basic device.

24 V

0 V

SRB ...*

SRB 402EM**

24

14

23

13

A2

X1

X2

A1

X2

X1

Fig. 2  * = basic module; ** = expander module

Example! The terminal designation of the basic module can 

deviate depending on the used type, please also observe the 

description of the basic module!

Internal wiring diagram

23 33 43 51

A1

A2

F1

K1

K1

K2

K2

K1

K1

K2

K2

X1

X2

13

24 34 44 52

61

62

14

Fig. 3

Содержание SRB402EM

Страница 1: ...eloped to execute safety related functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant The output expander module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding th...

Страница 2: ...and 43 44 meet the following requirements under observation of a PFH value assessment also refer to chapter 2 5 Safety classification Control category 4 PL e to DIN EN ISO 13849 1 Corresponds to SIL 3 to DIN EN 61508 2 SILCL 3 to DIN EN 62061 To determine the Performance Level PL of the entire safety function e g sensor logic actuator to DIN EN ISO 13849 1 an analysis of all relevant components is...

Страница 3: ... enclosure slightly tilted forwards in the DIN rail and push up until it latches in position 3 2 Dimensions All measurements in mm Device dimensions H W D SRB402EM 120 22 5 121 mm SRB402EM CC 130 22 5 121 mm 4 Electrical connection 4 1 General information for electrical connection As far as the electrical safety is concerned the protection against unintentional contact of the connected and therefo...

Страница 4: ...be disassembled in the de energised condition only Push up the bottom of the enclosure and hang out slightly tilted forwards 7 2 Disposal The output expander module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 8 Appendix 8 1 Wiring example Single channel control at terminal A1 of the SRB402EM expander module through a safety release of...

Страница 5: ...age Directive EMC Directive RoHS Directive 2006 95 EC 2004 108 EC 2011 65 EU 2014 35 EU 2014 30 EU 2011 65 EU Applied standards EN 60947 5 1 2004 AC 2005 A1 2009 Place and date of issue Wuppertal April 13 2016 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Internet www schmersal com We he...

Страница 6: ...o KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...