Operating instructions

Safety-monitoring module

SRB303SQP-SS

EN

6.  Wiring examples

6.1  Wiring example: Function SQP (External reset button)

Dual-channel control, shown for a safety edge and an external 

master reset button 

J

.

•  The safety-monitoring module is activated by the reset (after release) 

of the reset button (= detection of the trailing edge). Faults in the reset 

button, e.g. welded contacts or manipulations which could lead to an 

inadvertent restart, are detected in this configuration and will result in 

an inhibition of the operation.

•  Relay outputs: Suitable for 2-channel control, for increase in capacity 

or number of contacts by means of contactors or relays with positive-

guided contacts.

•  The control system recognises wire-breakage, earth faults and cross-

wire shorts in the monitoring circuit.

• 

S

 = Feedback circuit

Signalling outputs must not be used in safety circuits.

A1

A2

13

14

41

42

23

24

33

34

b)

3

51

52

X3

54

PE

S2

S2

S1

5

4

6

a)

c)

4

K1

K2

K3

K3

K2

K1

3

K

A

K

A

K

A

K

B

K

B

K

B

N

L1

6

5

S

J

Key

a) Safety inputs

b) Power

c) Processing

6.2  Wiring example: Function SS (Automatic start)

Dual-channel control, shown for a safety edge

•  The safety relay module is activated automatically when the feedback 

circuit is closed. 

•  Relay outputs: Suitable for 2-channel control, for increase in capacity 

or number of contacts by means of contactors or relays with positive-

guided contacts.

•  The control system recognises wire-breakage, earth faults and cross-

wire shorts in the monitoring circuit.

• 

S

 = Feedback circuit

Signalling outputs must not be used in safety circuits.

A1

A2

13

14

41

42

23

24

33

34

b)

3

51

52

X4

54

PE

S2

S2

S1

5

4

6

a)

c)

4

K1

K2

K3

K3

K2

K1

3

K

A

K

A

K

A

K

B

K

B

K

B

N

L1

6

5

S

Key

a) Safety inputs

b) Power

c) Processing

6.3  Sensor configuration

Connection of a safety edge

•  This control detects wire breakage, earth leakage and cross faults in 

the drive circuits.

• Category 3 – PL e to ISO 13849-1 possible.

3

5

4

6

a)

4

3

6

5

Key

 a) Safety edge

Connection of multiple safety edges

•  This control detects wire breakage, earth leakage and cross faults in 

the drive circuits.

• Category 3 – PL e to ISO 13849-1 possible.

3

5

4

6

a)

4

3

6

5

a)

4

3

6

5

Key

 a) Safety edge

Содержание SRB303SQP-SS

Страница 1: ...n accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety reg...

Страница 2: ...ine the Performance Level PL to ISO 13849 1 of the entire safety function e g sensor logic actuator an assessment of all relevant components is required The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data General data Standards EN 60204 1 IEC 60947 5 1 ISO 13849 1 IEC 62061 IEC 61508 EMC rating to EMC D...

Страница 3: ...IN rails to IEC 60715 Snap the bottom of the enclosure slightly tilted forwards in the DIN rail and push up until it latches in position 3 2 Dimensions All measurements in mm Device dimensions H W D SRB303SQP SS PC 100 x 22 5 x 121 mm SRB303SQP SS 120 x 22 5 x 121 mm SRB303SQP SS CC 130 x 22 5 x 121 mm 4 Electrical connection 4 1 General information for electrical connection The electrical connect...

Страница 4: ...KA KB KB KB N L1 6 5 S J Key a Safety inputs b Power c Processing 6 2 Wiring example Function SS Automatic start Dual channel control shown for a safety edge The safety relay module is activated automatically when the feedback circuit is closed Relay outputs Suitable for 2 channel control for increase in capacity or number of contacts by means of contactors or relays with positive guided contacts ...

Страница 5: ... enclosure for damage 4 Check the electrical function of the connected sensors and their influence on the safety monitoring module and the downstream actuators 7 3 Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check the correct fixing of the safety monitoring module 2 Check the cable for damages 3 Check electrical function If a manual fu...

Страница 6: ...in ID n 0035 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal July 17 2018 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Internet www schmersal com We hereby certify that the hereafter desc...

Отзывы: