1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  

the safety-monitoring module, personal hazards or damage  

to machinery or plant components cannot be excluded.  

The relevant requirements of the standard ISO 13856-2  

must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

The safety-monitoring module must only be used when the enclosure is 

closed, i.e. with the front cover fitted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB303SQP-SS-

➀➁

No. Option

Description

Plug-in screw clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 2.5 mm²;  

fine wire with ferrule: 0.25 … 2.5 mm²

CC

Plug-in cage clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 1.5 mm²;  

fine wire with ferrule: 0.25 … 1.5 mm²

PC

Screw clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 2.5 mm²;  

fine wire with ferrule: 0.25 … 2.5 mm²

24V

24 VAC/DC

230V

230 VAC

115V

115 VAC

Only if the action described in these operating instructions is 

carried out correctly will the safety function be safeguarded, 

including compliance with the Machinery Directive.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Purpose

The safety-monitoring modules for integration in safety circuits are 

designed for fitting in control cabinets. They are used for the safe 

evaluation of the signals of safety edges of the series STW-SL.

The safety function is defined as deactivating outputs 13-14, 23-24 and 

33-34 after actuation of the safety edge. The safety-relevant current 

paths with the outputs contacts 13-14, 23-24 and 33-34 meet the 

following requirements under observation of a PFH value assessment 

(also refer to chapter 2.5 "Safety classification"):

• Control category 3 - PL e to ISO 13849-1  

• SIL 3 to IEC 61508-2  

• SILCL 3 to IEC 62061

To determine the Performance Level (PL) to ISO 13849-1 of the entire 

safety function (e.g. sensor, logic, actuator), an assessment of all 

relevant components is required.

The entire concept of the control system, in which the 

safety component is integrated, must be validated to the 

relevant standards.

2.4  Technical data

General data: 

Standards:

 

EN 60204-1, IEC 60947-5-1; ISO 13849-1,  

IEC 62061, IEC 61508

EMC rating: 

 

to EMC Directive

Air clearances and creepage distances:

 

to IEC 60664-1

Mounting:

 

standard rail in accordance with IEC 60715

Terminal designations:

 

IEC 60947-1

Electrical characteristics: 

Rated operating voltage U

e

24 VDC –15% / +20%,  

residual ripple max. 10%,  

24 VAC –15% / +10%,  

115VAC / 230VAC VAC –15% / +6%

Frequency range:

 

50 Hz/60 Hz

Power consumption:

 

24V version: max. 3.0 W / 7.5 VA,  

115V version: max. 6.5 VA,  

230V version: max. 6.0 VA

Fuse rating for the operating voltage:

 

Internal electronic trip,  

tripping current > 500 mA,  

Reset after disconnection of supply voltage

Insulation values in accordance with IEC 60664-1: 

 

Rated insulation voltage U

i

:

 

 

- Safety contacts:

 

250 V 

Rated impulse withstand voltage U

imp

:

 

 

- Safety contacts 13-14, 23-24, 33-34:

 

4 kV 

Overvoltage category:

 III 

Degree of pollution:

 2

Pull-in delay for automatic start:

 

typ. 80 ms

Pull-in delay with reset button:

 

typ. 15 ms

Drop-out delay:

 

typ. 30 ms

Drop-out delay on "supply failure":

 

typ. 60 ms

Bridging in case of voltage drops: 

 

typ. 40 ms

Control current circuits/inputs: 

 

- Inputs 5, 6:

 

24 VDC / 5 mA  

- Input X3:

 

24 VDC, start impulse 20 mA / 20 ms  

- Input X4:

 

24 VDC / 25 mA  

- Input S2 (with reset button):

 

24 VDC, start impulse 20 mA / 20 ms  

- Input S2 (auto start):

 

24 VDC / 25 mA

Safety edge STW-SL: 

Cable lengths:

 

0.2 m up to 24 m

Conduction resistance:

 

5 kΩ / m

Relay outputs: 

Switching capacity of the safety contacts:

 

13-14; 23-24; 33-34:  

max. 250 V, 6 A ohmic (inductive in case of  

appropriate protective wiring);  

min. 10 V / 10 mA

Fuse rating of the safety contacts: 

 

external (I

k

 = 1000 A)  

to IEC 60947-5-1  

Safety fuse 8 A quick blow, 6.3 A slow blow

Utilisation category to IEC 60947-5-1:

 

AC-15: 230 VAC / 6 A  

DC-13: 24 VDC / 6 A

Switching capacity of the auxiliary contacts:

 

41-42: 24 VDC / 2 A  

51-52, 51-54: 24 VDC / 1 A

Fuse rating for the auxiliary contact:

 

external (I

k

 = 1000 A)  

to IEC 60947-5-1  

41-42: Safety fuse 2.5 A quick blow, 2 A slow blow  

51-52, 51-54: Safety fuse 1.25 A quick blow, 1 A slow blow

Electrical life:

 

Derating curve available on request

Mechanical life:

 

10 million operations

Safety contact values:

 

resistance max. 100 mΩ, AgSnO, 

 

self-cleaning, positive action

Mechanical data: 

Connection type:

 

refer to 2.1 Ordering code

Cable section:

 

refer to 2.1 Ordering code

Connecting cable:

 

rigid or flexible

Tightening torque for the terminals:

 

0.5 Nm

Material of enclosure:

 

glass-fibre reinforced thermoplastic, ventilated

Weight:

 

24V-version: 320 g  

115 / 230V-version: 470 g

Содержание SRB303SQP-SS

Страница 1: ...n accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety reg...

Страница 2: ...ine the Performance Level PL to ISO 13849 1 of the entire safety function e g sensor logic actuator an assessment of all relevant components is required The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data General data Standards EN 60204 1 IEC 60947 5 1 ISO 13849 1 IEC 62061 IEC 61508 EMC rating to EMC D...

Страница 3: ...IN rails to IEC 60715 Snap the bottom of the enclosure slightly tilted forwards in the DIN rail and push up until it latches in position 3 2 Dimensions All measurements in mm Device dimensions H W D SRB303SQP SS PC 100 x 22 5 x 121 mm SRB303SQP SS 120 x 22 5 x 121 mm SRB303SQP SS CC 130 x 22 5 x 121 mm 4 Electrical connection 4 1 General information for electrical connection The electrical connect...

Страница 4: ...KA KB KB KB N L1 6 5 S J Key a Safety inputs b Power c Processing 6 2 Wiring example Function SS Automatic start Dual channel control shown for a safety edge The safety relay module is activated automatically when the feedback circuit is closed Relay outputs Suitable for 2 channel control for increase in capacity or number of contacts by means of contactors or relays with positive guided contacts ...

Страница 5: ... enclosure for damage 4 Check the electrical function of the connected sensors and their influence on the safety monitoring module and the downstream actuators 7 3 Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check the correct fixing of the safety monitoring module 2 Check the cable for damages 3 Check electrical function If a manual fu...

Страница 6: ...in ID n 0035 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal July 17 2018 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Internet www schmersal com We hereby certify that the hereafter desc...

Отзывы: