schmersal SRB-E-402ST Скачать руководство пользователя страница 2

2

Operating instructions

Safety-monitoring module

SRB-E-402ST

EN

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety-monitoring module must be exclusively used in accordance 

with the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

The entire concept of the control system, in which the safety 

component is integrated, must be validated to EN ISO 13849-2.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  

the safety-monitoring module, personal hazards or damage  

to machinery or plant components cannot be excluded.  

The relevant requirements of the standards ISO 14119 and 

EN ISO 13850 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

The safety relay module is to be operated in an area in which access  

by personnel is restricted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB-E-402ST-

No. Option

Description

Plug-in screw clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 2.5 mm²;  

fine wire with ferrule: 0.25 … 2.5 mm²

CC

Plug-in cage clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 1.5 mm²;  

fine wire with ferrule: 0.25 … 1.5 mm²

Only if the action described in these operating instructions is 

carried out correctly will the safety function be safeguarded, 

including compliance with the Machinery Directive.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are 

designed for fitting in control cabinets. They are used for the safe 

evaluation of the signals of positive break position switches or safety 

sensors for safety functions on sliding, hinged and removable safety 

guards as well as emergency stop control devices, safety solenoid 

switches and AOPD's.

The safety function is defined as deactivating outputs Q1, Q2 and 

13/14, 23/24 when inputs S12, S32 and/or S22, S42 are opened. 

Taking account of a PFH value assessment, the safety-relevant current 

paths meet the following requirements (see also chapter 2.6 “Safety 

classification”):

• Control category 4 - PL e to EN ISO 13849-1 

• SIL 3 to IEC 61508 

• SILCL 3 to DIN EN 62061

To determine the Performance Level (PL) to EN ISO 13849-1 of the 

entire safety function (e.g. sensor, logic, actuator), an assessment of all 

relevant components is required.

2.4  Technical data

General data 

Standards:

 

IEC/EN 60204-1, EN 60947-5-1; EN ISO 13849-1,  

IEC/EN 62061, IEC 61508

EMC rating: 

 

to EMC Directive

Air clearances and creepage distances: 

 

to IEC/EN 60664-1

Mounting:

 

standard DIN rail to EN 60715

Terminal designations:

 

EN 60947-1

Electrical characteristics: 

Rated operating voltage U

e

24 VDC –20%/+20%,  

residual ripple max. 10%

Mains unit/mains power supply:

  SELV network as per DIN EN 60950;  

mains power supply must harmonise with device  

safety (characteristic/melting property)  

so that triggering is assured. 

Power consumption: 

3.6 W (+ load of the safety outputs)

Fuse rating for the operating voltage:

 

we recommend a circuit 

breaker type Z (max. 16 A) or a fine 

fuse (max. 15 A, delayed action)

UL Rating of external fuse:

 

max. 16 A, only use fuses in  

accordance with UL 248 series

Содержание SRB-E-402ST

Страница 1: ...e could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Ap...

Страница 2: ...elay module is to be operated in an area in which access by personnel is restricted 2 Product description 2 1 Ordering code This operating instructions manual applies to the following types SRB E 402S...

Страница 3: ...0 Inductive consumers provision is to be made for suitable protective wiring for suppression Mechanical data Connection type refer to 2 1 Cable section refer to 2 1 Connecting cable rigid or flexible...

Страница 4: ...etic Compatibility EMC of DIN EN 60204 1 4 2 Coding of connecting terminals 5 Operating principle and settings 5 1 Description of the terminals and LED indications Pin Function LED Function A1 Operati...

Страница 5: ...sition C Application 1 is deleted Lights up Flashes Flashes Flashes Flashes Setting cycle active Application 1 is deleted No valid application stored Flashes SRB E ready for new applications Select mo...

Страница 6: ...of contactors or relays with positive guided contacts H2 Feedback circuit Signalling outputs must not be used in safety circuits 6 Diagnostic 6 1 LED indications LED Function Display type RUN Ready f...

Страница 7: ...position 6 Rotary knob position 2 Rotary knob position 7 Rotary knob position 3 Rotary knob position 8 Rotary knob position 4 Rotary knob position 9 Rotary knob position 5 Rotary knob position 10 7 4...

Страница 8: ...S32 S42 S31 S41 S32 S42 S31 S41 24VDC S12 S22 Rotary knob position Function 5 Reset button detection of the trailing edge 6 Reset without monitoring autostart Two hand control type IIIC safety functi...

Страница 9: ...chine Machine n Machine type Module n Configured application mode 1 Configured application mode 2 Set on date Signature of the responsible person 8 5 Maintenance A regular visual inspection and functi...

Страница 10: ...35 EC prototype test certificate 01 205 5365 00 18 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal J...

Отзывы: