schmersal SRB-E-212ST Скачать руководство пользователя страница 2

2

Operating instructions

Safety-monitoring module

SRB-E-212ST / SRB-E-322ST

EN

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety-monitoring module must be exclusively used in accordance 

with the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

The entire concept of the control system, in which the safety 

component is integrated,  

must be validated to the relevant standards.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  

the safety-monitoring module, personal hazards or damage  

to machinery or plant components cannot be excluded. 

The relevant requirements of the standards ISO 14119 and 

ISO 13850 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

The safety relay module is to be operated in an area in which access  

by personnel is restricted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB-E-212ST-

SRB-E-322ST-

No. Option

Description

Plug-in screw clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 2.5 mm²;  

fine wire with ferrule: 0.25 … 2.5 mm²

CC

Plug-in cage clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 1.5 mm²;  

fine wire with ferrule: 0.25 … 1.5 mm²

Only if the action described in these operating instructions is 

carried out correctly will the safety function be safeguarded, 

including compliance with the Machinery Directive.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are 

designed for fitting in control cabinets. They are used for the safe 

evaluation of the signals of positive break position switches or safety 

sensors for safety functions on sliding, hinged and removable safety 

guards as well as emergency stop control devices, safety solenoid 

switches and AOPD's.

The safety function is defined as deactivating outputs Qt1, Qt2 and 

13/14, 23/24, 33/34 when inputs S12 and/or S22 are opened. Taking 

account of a PFH value assessment, the safety-relevant current 

paths meet the following requirements (see also chapter 2.6 “Safety 

classification”):

- Control category 4 - PL e to ISO 13849-1  

- SIL 3 to IEC 61508  

- SILCL 3 to IEC 62061

To determine the Performance Level (PL) to ISO 13849-1 of the entire 

safety function (e.g. sensor, logic, actuator), an assessment of all 

relevant components is required.

Содержание SRB-E-212ST

Страница 1: ...ure to comply with this warning notice could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Appropriate use 2 1 5 General safety instructions 2 1 6 Warning about misuse 2 1 7 Exclusion of liability 2 2 Product description 2 1 Ordering code 2 2 2 Special ver...

Страница 2: ...pt no liability for damages resulting from the use of unauthorised spare parts or accessories For safety reasons invasive work on the device as well as arbitrary repairs conversions and modifications to the device are strictly forbidden the manufacturer shall accept no liability for damages resulting from such invasive work arbitrary repairs conversions and or modifications to the device The safet...

Страница 3: ...on category to IEC 60947 5 1 AC 15 230 V 4 A DC 13 24 V 4 A Switching capacity of the auxiliary contacts 41 42 24 VDC 1 A Fuse rating for the auxiliary contact safety fuse 2 5 A quick blow 2 A slow blow Safety contact values resistance max 100 mΩ AgNi self cleaning positive action Electrical life refer to 2 5 Mechanical life 10 million operations Semi conductor outputs Switching capacity of the sa...

Страница 4: ... for the relay contacts Diverging applications upon request Contact load nop y tcycle 20 880 000 0 6 min 40 330 000 1 6 min 60 110 000 5 0 min 80 44 000 12 0 min 100 17 600 30 0 min 3 Mounting 3 1 General mounting instructions Mounting snaps onto standard DIN rails to EN 60715 Hook bottom of enclosure in DIN rail and push down until it engages in position 3 2 Dimensions All measurements in mm Devi...

Страница 5: ...fety outputs STOP 0 Out 1 Outputs activated For flash code see section 5 4 Qt1 Qt2 Safety outputs STOP 1 Out 2 Outputs activated For flash code see section 5 4 1 0 S11 S12 S21 S22 A1 A2 X3 X2 X7 Qt1 Y2 Y1 SRB E 212ST 24 23 14 13 Out 2 time s RUN ERR ln 1 ln 2 Out 1 mode 1 0 S11 S12 S21 S22 A1 A2 X3 X2 Qt2 Qt1 X7 Y2 SRB E 322ST 24 23 14 13 42 41 34 33 time s RUN ERR ln 1 ln 2 Out 1 Out 2 mode Adjus...

Страница 6: ...e Rotary mode switch Rotary time switch System response LED indications RUN In 1 In 2 Out Factory setting Position 1 0 s Ready for application 1 Switch operating voltage on Position 1 Without connected sensors Lights up Turn to position C Application 1 is deleted Lights up Flashes Flashes Flashes Setting cycle active Application 1 is deleted No valid application stored Flashes SRB E ready for new ...

Страница 7: ...Continuously lit Not a valid application Flashes In 1 Input S12 closed Continuously lit Time window for synchronicity exceeded Flashes quickly Second channel input S22 has not opened Flashes slowly In 2 Input S22 closed Continuously lit Time window for synchronicity exceeded Flashes quickly Second channel input S12 has not opened Flashes slowly Out 1 Safety output STOP 0 ON Continuously lit No rel...

Страница 8: ...1 23 13 33 41 24 14 34 42 K1 K2 L1 KA KB N KC KD a b c d e f Key a Safety inputs b Safety outputs c Signalling outputs d Clock outputs e Processing f Power 7 2 Application example Dual channel control shown for a guard door monitor with two position switches where one has a positive break contact with external reset button J Relay outputs Suitable for 2 channel control for increase in capacity or ...

Страница 9: ...ther suitable measures X2 J S11 S21 X2 24VDC J Reset button detection of the trailing edge Reset without monitoring autostart Rotary knob position 1 Rotary knob position 6 Rotary knob position 2 Rotary knob position 7 Rotary knob position 3 Rotary knob position 8 Rotary knob position 4 Rotary knob position 9 Rotary knob position 5 Rotary knob position 10 7 4 Feedback circuit Release signal Suitabl...

Страница 10: ...ng autostart 8 Set up and maintenance 8 1 Commissioning The safety relay module features protection class IP54 for installation in a switch cabinet The safety relay module is delivered ready for operation Application 1 is preset in the factory 8 2 Functional testing The safety function of the safety monitoring module must be tested The following conditions must be previously checked and met 1 Corr...

Страница 11: ... must be replaced 9 Disassembly and disposal 9 1 Disassembly The safety monitoring module must be disassembled in a de energised condition only 9 2 Disposal The safety monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 10 Appendix 10 1 Wiring circuit information Wiring example for cascading via safety input X7 Safety output...

Страница 12: ...ny Internet www schmersal com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives Name of the component SRB E 212ST SRB E 322ST Type See ordering code Description of the component Relay safety combination for emergency stop circuits guard door monitoring solenoid safety switches and AOPDs Relevant Direc...

Отзывы: