schmersal SRB-E-212ST Скачать руководство пользователя страница 12

12

EN

SRB-E-212ST

 / SRB-E-322ST

-C-EN

Operating instructions

Safety-monitoring module

SRB-E-212ST / SRB-E-322ST

11. 

EU Declaration of conformity

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: [email protected]

Internet: http://www.schmersal.com

Place and date of issue:

Wuppertal, July 12, 2018

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

Name of the component:

SRB-E-212ST

SRB-E-322ST

Type:

See ordering code

Description of the component:

Relay-safety combination for emergency stop circuits,  

guard door monitoring, solenoid safety switches and AOPDs

Relevant Directives:

Machinery Directive

EMC-Directive

RoHS-Directive

2006/42/EC

2014/30/EU

2011/65/EU

Applied standards:

 ISO 13849-1:2015,

ISO 13849-2:2012,

IEC 61508 parts 1-7:2010,

IEC 62061:2015

Notified body for the prototype test:

TÜV Rheinland Industrie Service GmbH

Alboinstr. 56, 12103 Berlin

ID n°: 0035

EC-prototype test certificate:

01/205/5365.00/18

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

Содержание SRB-E-212ST

Страница 1: ...ure to comply with this warning notice could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Appropriate use 2 1 5 General safety instructions 2 1 6 Warning about misuse 2 1 7 Exclusion of liability 2 2 Product description 2 1 Ordering code 2 2 2 Special ver...

Страница 2: ...pt no liability for damages resulting from the use of unauthorised spare parts or accessories For safety reasons invasive work on the device as well as arbitrary repairs conversions and modifications to the device are strictly forbidden the manufacturer shall accept no liability for damages resulting from such invasive work arbitrary repairs conversions and or modifications to the device The safet...

Страница 3: ...on category to IEC 60947 5 1 AC 15 230 V 4 A DC 13 24 V 4 A Switching capacity of the auxiliary contacts 41 42 24 VDC 1 A Fuse rating for the auxiliary contact safety fuse 2 5 A quick blow 2 A slow blow Safety contact values resistance max 100 mΩ AgNi self cleaning positive action Electrical life refer to 2 5 Mechanical life 10 million operations Semi conductor outputs Switching capacity of the sa...

Страница 4: ... for the relay contacts Diverging applications upon request Contact load nop y tcycle 20 880 000 0 6 min 40 330 000 1 6 min 60 110 000 5 0 min 80 44 000 12 0 min 100 17 600 30 0 min 3 Mounting 3 1 General mounting instructions Mounting snaps onto standard DIN rails to EN 60715 Hook bottom of enclosure in DIN rail and push down until it engages in position 3 2 Dimensions All measurements in mm Devi...

Страница 5: ...fety outputs STOP 0 Out 1 Outputs activated For flash code see section 5 4 Qt1 Qt2 Safety outputs STOP 1 Out 2 Outputs activated For flash code see section 5 4 1 0 S11 S12 S21 S22 A1 A2 X3 X2 X7 Qt1 Y2 Y1 SRB E 212ST 24 23 14 13 Out 2 time s RUN ERR ln 1 ln 2 Out 1 mode 1 0 S11 S12 S21 S22 A1 A2 X3 X2 Qt2 Qt1 X7 Y2 SRB E 322ST 24 23 14 13 42 41 34 33 time s RUN ERR ln 1 ln 2 Out 1 Out 2 mode Adjus...

Страница 6: ...e Rotary mode switch Rotary time switch System response LED indications RUN In 1 In 2 Out Factory setting Position 1 0 s Ready for application 1 Switch operating voltage on Position 1 Without connected sensors Lights up Turn to position C Application 1 is deleted Lights up Flashes Flashes Flashes Setting cycle active Application 1 is deleted No valid application stored Flashes SRB E ready for new ...

Страница 7: ...Continuously lit Not a valid application Flashes In 1 Input S12 closed Continuously lit Time window for synchronicity exceeded Flashes quickly Second channel input S22 has not opened Flashes slowly In 2 Input S22 closed Continuously lit Time window for synchronicity exceeded Flashes quickly Second channel input S12 has not opened Flashes slowly Out 1 Safety output STOP 0 ON Continuously lit No rel...

Страница 8: ...1 23 13 33 41 24 14 34 42 K1 K2 L1 KA KB N KC KD a b c d e f Key a Safety inputs b Safety outputs c Signalling outputs d Clock outputs e Processing f Power 7 2 Application example Dual channel control shown for a guard door monitor with two position switches where one has a positive break contact with external reset button J Relay outputs Suitable for 2 channel control for increase in capacity or ...

Страница 9: ...ther suitable measures X2 J S11 S21 X2 24VDC J Reset button detection of the trailing edge Reset without monitoring autostart Rotary knob position 1 Rotary knob position 6 Rotary knob position 2 Rotary knob position 7 Rotary knob position 3 Rotary knob position 8 Rotary knob position 4 Rotary knob position 9 Rotary knob position 5 Rotary knob position 10 7 4 Feedback circuit Release signal Suitabl...

Страница 10: ...ng autostart 8 Set up and maintenance 8 1 Commissioning The safety relay module features protection class IP54 for installation in a switch cabinet The safety relay module is delivered ready for operation Application 1 is preset in the factory 8 2 Functional testing The safety function of the safety monitoring module must be tested The following conditions must be previously checked and met 1 Corr...

Страница 11: ... must be replaced 9 Disassembly and disposal 9 1 Disassembly The safety monitoring module must be disassembled in a de energised condition only 9 2 Disposal The safety monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 10 Appendix 10 1 Wiring circuit information Wiring example for cascading via safety input X7 Safety output...

Страница 12: ...ny Internet www schmersal com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives Name of the component SRB E 212ST SRB E 322ST Type See ordering code Description of the component Relay safety combination for emergency stop circuits guard door monitoring solenoid safety switches and AOPDs Relevant Direc...

Отзывы: