Operating instructions

Safety light curtain / safety light grid

SLC 220

SLG 220

EN

The information contained in this operating instructions manual is pro-

vided without liability and is subject to technical modifications.

If multiple safety components are wired in series, the Per-

formance Level to EN ISO 13849-1 will be reduced due to the 

restricted error detection under certain circumstances. The 

entire concept of the control system, in which the safety com-

ponent is integrated, must be validated to EN ISO 13849-2.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Additional measures could be required to ensure that the electro-sensi-

tive device does not present a dangerous breakdown, when other forms 

of light beams are available in a special application (e.g. use of wireless 

control devices on cranes, radiation of welding sparks or effects of 

stroboscopic lights).

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of the 

safety switchgear, personal hazards or damage to machin-

ery or plant components cannot be excluded. The relevant 

requirements of the standards EN ISO 13855 (successor of 

EN 999) & EN ISO 13857 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages result-

ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modifications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modifications 

to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SLC 220-E/R

-

RFB-

➂➃

No. Option

Description

xxxx

Protection field heights in mm available lengths: 

0175*, 0250*, 0325, 0475, 0625, 0775, 0925, 

1075, 1225, 1375, 1525, 1675

30, 80

Resolution 30, 80 mm

Range 0.3 m ... 6 m

H

Range 4 m ... 14 m (high range)

M

Master function

S

Slave function*

* only for resolution 30 mm

SLG 220-E/R

RF-

➁➂

No. Option

Description

Distance between outermost beams:

0500-02

500 mm, 2-beam

0800-03

800 mm, 3-beam

0900-04

900 mm, 4-beam

Range 0.3 m ... 6 m

H

Range 5 m ... 30 m (high range)

M

Master function

S

Slave function

Only if the information described in this operating instruc-

tions manual are realised correctly, the safety function and 

therefore the compliance with the Machinery Directive is 

maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Scope of delivery and accessories

Accessories included in delivery

Mounting kit MS-1000

The kit comprises 4 rotating mounting angles and 16 mounting screws 

for fixing to the end caps.

Mounting kit MS-1010

Consisting of 2 centre supports (as from protected field ≥ 1075 mm).

Test rod PLS-01

The test rod is used for testing the protection field. The PLS-01 test rod 

has a diameter of 30 mm.

Optional accessories

Safety relays

For processing the signal outputs OSSD 1 and OSSD 2 of the  SLC/

SLG 220 series, the use of a safety relay is recommended. This safety 

relay must meet the safety requirements for the chosen safety level. 

More technical information regarding safety switching appliances can 

be found on our homepage  

www.schmersal.com.

Connecting cable
Item number

Designation

Description

Length

1207728

KA-0904

Female connector M12, 8-pole 5 m

1207729

KA-0905

Female connector M12, 8-pole 10 m

1207730

KA-0908

Female connector M12, 8-pole 20 m

Junction cable for cascaded systems
Item number

Designation

Description

Length

1207731

KA-0907

Female connector M12, 

6-pole

300 mm

The connecting and junction cables can be used for transmitter and re-

ceiver.

BUS converter NSR-0700

Converter for parametrization and diagnostics. Detailled information can 

be found in the operating instructions manual of the NSR-0700.

Included in delivery: integrated connecting cable, PC-software WIN 95, 

98, NT, XP; RS 232 connection. (L x W x H, 122 x 60 x 35 mm)

MSD2 Vibration damper

Kit comprising: 8 vibration dampers 15 x 20 mm, 8x M5 socket head 

cap screws, 8 spring washers. The MSD2 vibration damper kit must 

be used for damping vibrations and oscillations on the SLC/SLG 220. 

For applications with higher mechanical stresses, we recommend the 

MSD2 kit. In this way, the availability of the SLC/SLG 220 is increased.

2.4  Destination and use

The SLC/SLG is a non-contact, self-testing safety guard, which is used 

for the protection of hazardous points, hazardous areas and machine 

accesses. If one or more light beams are interrupted, the hazardous 

movement must be stopped.

The user must evaluate and design the safety chain in accord-

ance with the relevant standards and the required safety level.

Содержание SLC 220

Страница 1: ...ct description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailin...

Страница 2: ...nge 0 3 m 6 m H Range 5 m 30 m high range M Master function S Slave function Only if the information described in this operating instruc tions manual are realised correctly the safety function and the...

Страница 3: ...l reset 20 ms 1 0 s signal trans mission in case of trailing edge Start interlock 250 ms 1500 ms adjustable LED indications transmitter Transmitting status restart LED indications receiver OSSD ON OSS...

Страница 4: ...ton 2 8 3 Fixed blanking The SLC 220 can blank stationary parts in the protection field Multiple protection field areas can be blanked Fixed blanking area E1 R1 The range of the fixed blanking can be...

Страница 5: ...nsion is possible up to max 96 lines and a pro tection field height of 2 45 m with the same resolution The connection of the systems master and slave is realised with the pre wired connector KA 0907 3...

Страница 6: ...the following elements Stopping time of the machine calculation by run on time measure ment Response time of the machine and the safety light curtain and the downstream relay entire safety guard Appr...

Страница 7: ...41 mm The following mounting heights to EN 999 must be observed Number of beams Mounting height above reference floor Floor in mm 2 400 900 3 300 700 1100 4 300 600 900 1200 The successor standards of...

Страница 8: ...2 1289 1 8 SLC 220 E R1375 30 RFB 1375 0 8 1422 1 5 1439 2 0 SLC 220 E R1525 30 RFB 1525 0 8 1572 1 5 1589 2 0 SLC 220 E R1675 30 RFB 1675 0 8 1722 1 5 1739 2 0 All versions with resolution 30 and 80...

Страница 9: ...fety light curtain safety light grid EN Accessories Mounting kit MS 1000 5 5 5 14 25 39 27 46 5 5 8 35 20 Centre support MS 1010 3 8 19 1 42 4 38 1 38 1 43 2 46 5 27 20 30 43 12 8 19 2 5 5 3 5 R 2 5 C...

Страница 10: ...RS485 B grey 24V brown 0V blue RS485 A pink RS485 B grey Signal quality white 24V brown 0V blue OSSD2 yellow OSSD1 green Earth connection Restart interlock active this connection is omitted connect S2...

Страница 11: ...ies Conditions For safety reasons all inspection results must be archived The operat ing principle of the SLC SLG and the machine must be known in order to be able conducting an inspection If the fitt...

Страница 12: ...D OFF contactor control input must show 24V Switch on only after POWER OFF ON 1 flashes Receiver configuration error or communication error Check transmitter and receiver configuration reparameterize...

Страница 13: ...manner in accordance with the national prescriptions and legislations 8 Appendix 8 1 Contact Consultancy Sales K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal...

Страница 14: ...h Loss M ddinghofe 30 42279 Wuppertal Notiied body for the prototype test T V Nord Cert GmbH Langemarckstr 20 45141 Essen ID n 0044 EC prototype test certiicate n 44 205 10 555867 004 Safety Control G...

Отзывы: