schmersal SLC 220 Скачать руководство пользователя страница 14

14

Operating instructions

Safety light curtain / safety light grid

SLC 220

SLG 220

EN

SLC 220-B-EN

9.  Declaration of conformity

The currently valid declaration of conformity can be down-

loaded from the internet at www.schmersal.net.

9.1  EC Declaration of conformity

Name of the safety component / type:

SLC 220

SLG 220

Description of the safety component:

Safety light curtain / safety light grid

Harmonised EC-Directives:

2006/42/EC EC-Machinery Directive

2004/108/EC EMC-Directive

Applied standards:

EN 61496-1:2004 + A1 2008

CLC/TS 61496-2:2006

EN ISO 13849-1:2008; PL d

EN 62061:2005; SIL 2

Person authorised for the compilation of 

the technical documentation:

Ulrich Loss

Möddinghofe 30

42279 Wuppertal

Notiied body for the prototype test:

TÜV Nord Cert GmbH

Langemarckstr.20

45141 Essen

ID n°: 0044

EC-prototype test certiicate:

n° 44 205 10 555867 004

Safety Control GmbH

Am Industriepark 33

D-84453 Mühldorf / Inn

Telefon  +49 - (0)86 31 - 187 - 9 60

Telefax  +49 - (0)86 31 - 187 - 9 61

E-Mail:   [email protected]

Place and date of issue:

Wuppertal, September 9, 2009

Authorised signature

Christian Spranger

Managing Director

Authorised signature

Klaus Schuster

Managing Director

EC Declaration of conformity

Translation of the original declaration of conformity

valid as of December 29, 2009

Safety Control GmbH

Am Industriepark 33

84453 Mühldorf / Inn

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described safety components both in its basic design and con-

struction conform to the applicable European Directives.

Содержание SLC 220

Страница 1: ...ct description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailin...

Страница 2: ...nge 0 3 m 6 m H Range 5 m 30 m high range M Master function S Slave function Only if the information described in this operating instruc tions manual are realised correctly the safety function and the...

Страница 3: ...l reset 20 ms 1 0 s signal trans mission in case of trailing edge Start interlock 250 ms 1500 ms adjustable LED indications transmitter Transmitting status restart LED indications receiver OSSD ON OSS...

Страница 4: ...ton 2 8 3 Fixed blanking The SLC 220 can blank stationary parts in the protection field Multiple protection field areas can be blanked Fixed blanking area E1 R1 The range of the fixed blanking can be...

Страница 5: ...nsion is possible up to max 96 lines and a pro tection field height of 2 45 m with the same resolution The connection of the systems master and slave is realised with the pre wired connector KA 0907 3...

Страница 6: ...the following elements Stopping time of the machine calculation by run on time measure ment Response time of the machine and the safety light curtain and the downstream relay entire safety guard Appr...

Страница 7: ...41 mm The following mounting heights to EN 999 must be observed Number of beams Mounting height above reference floor Floor in mm 2 400 900 3 300 700 1100 4 300 600 900 1200 The successor standards of...

Страница 8: ...2 1289 1 8 SLC 220 E R1375 30 RFB 1375 0 8 1422 1 5 1439 2 0 SLC 220 E R1525 30 RFB 1525 0 8 1572 1 5 1589 2 0 SLC 220 E R1675 30 RFB 1675 0 8 1722 1 5 1739 2 0 All versions with resolution 30 and 80...

Страница 9: ...fety light curtain safety light grid EN Accessories Mounting kit MS 1000 5 5 5 14 25 39 27 46 5 5 8 35 20 Centre support MS 1010 3 8 19 1 42 4 38 1 38 1 43 2 46 5 27 20 30 43 12 8 19 2 5 5 3 5 R 2 5 C...

Страница 10: ...RS485 B grey 24V brown 0V blue RS485 A pink RS485 B grey Signal quality white 24V brown 0V blue OSSD2 yellow OSSD1 green Earth connection Restart interlock active this connection is omitted connect S2...

Страница 11: ...ies Conditions For safety reasons all inspection results must be archived The operat ing principle of the SLC SLG and the machine must be known in order to be able conducting an inspection If the fitt...

Страница 12: ...D OFF contactor control input must show 24V Switch on only after POWER OFF ON 1 flashes Receiver configuration error or communication error Check transmitter and receiver configuration reparameterize...

Страница 13: ...manner in accordance with the national prescriptions and legislations 8 Appendix 8 1 Contact Consultancy Sales K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal...

Страница 14: ...h Loss M ddinghofe 30 42279 Wuppertal Notiied body for the prototype test T V Nord Cert GmbH Langemarckstr 20 45141 Essen ID n 0044 EC prototype test certiicate n 44 205 10 555867 004 Safety Control G...

Отзывы: