Installation manual
PSC1-C-10 Installation manual V2.6
Page 128 of 173
Version: 57E
7.3.2
Reset timing
An "Internal Reset" is triggered with the falling edge of the reset input.
Reset_In
Reset_Status
7.3.3
Reset function
Function unit
General
Reset
Internal
Reset
Function
Fatal error
X
Reset error
Alarm
X
X
Reset alarm
Monitoring functions
X
X
Resetting a triggered monitoring function
Flip-flop
X
X
(1)
Status = Reset
Timer
X
X
Timer = 0
(1)
Attention:
As the start/reset element is configured here as a logic reset and connected as an element to a flip-flop element,
the flip-flop is reset at high signal...
The status of the monitoring functions is formed again after a reset:
•
If the limits configured are exceeded, process values do not cause the output status of the
monitoring function to change
•
Time-based functions - timers reset the output status of the monitoring function. Triggering
only occurs if the limits configured are exceeded again
Pos_Ist
Reset_In
SOS_Result
SOS_Pos_Max
SOS_Pos_Min
Pos_Is t > SOS_Pos_Max
Process value (position) => no change to the output status on reset in the alarm state
Содержание PSC1-C-10 Series
Страница 1: ...Installation manual for PSC1 modules Series PSC1 C 10 PSC1 C 10 SDMx PSC1 E 3x...
Страница 98: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 98 of 173 Version 57E 2 I 09 3 I 10 4 I 11...
Страница 140: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 140 of 173 Version 57E...
Страница 153: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 153 of 173 Version 57E Example for a hazard analysis...