5.12.5
Extended monitoring with 2 proximity switches
For extended monitoring the two status states of the counting signals are logically compared. The
cogwheel must always guarantee a 'high' level of at least one of the two input signals
Signal A
Signal B
Result
0
0
False
1
0
True
0
1
True
1
1
True
In addition, the following parameters must be met.
Max. blanking 0 signal: 50%
Min. overlap:
10%
The easiest way to achieve this is to use a 2: 1 division. This also simplifies the correct assembly of the
associated sensors. The following picture illustrates this for a radial arrangement of the sensors:
Signal level:
24 V/0 V
Max. count pulse frequency:
4 kHz
Min. count pulse frequency:
1 Hz
De-bounced switching logic
Diagnostics:
Diagnostics
Parameter
Fault threshold
Monitoring of supply voltage
not possible
Fixed value 24V
+/- 20% +/-2% (measuring
tolerance)
T=100%
33,3%
16,7
33,3%
16,7
Desired theoretical waveform
Содержание PSC1-C-10 Series
Страница 1: ...Installation manual for PSC1 modules Series PSC1 C 10 PSC1 C 10 SDMx PSC1 E 3x...
Страница 98: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 98 of 173 Version 57E 2 I 09 3 I 10 4 I 11...
Страница 140: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 140 of 173 Version 57E...
Страница 153: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 153 of 173 Version 57E Example for a hazard analysis...