5.10
Connection of position and speed sensors
5.10.1
General instructions
Depending on the module type, the PSC1 module (PSC1-C-10-SDMx) has external encoder interfaces
for the connection of the usual industrial incremental and absolute encoders. The encoder interfaces
can be configured for incremental, SIN/COS, absolute SSI encoders or for proximity switches.
In addition, it is possible to connect two sensors that generate incremental signals (for instance
proximity switches) to the counter inputs on the PSC1 module. The signals must be read using a
normal track and a complementary track.
IMPORTANT:
Power is supplied to the encoder system via the terminals provided on the PSC1 module. This voltage
is supplied to the encoder connector and is monitored by an internal diagnostic process.
If the sensor is supplied with an external voltage, this must be routed via the encoder connector. The
related terminal (encoder power supply) on the PSC1 module remains unused.
If an external sensor supply voltage is not fed back via the encoder connector, the failure of this supply
is to be included in the fault analysis for the overall system. In particular, it is therefore necessary to
demonstrate that if the specified operating voltage for the encoder system is dropped below /
exceeded, this fault will be detected or can be excluded.
EMC measures such as screening etc. are to be observed.
The two encoders must not interact with each other. This applies for both the electrical and the
mechanical part.
If both encoders are coupled to the device to be monitored via common mechanical parts, the
connection must be of a positively locking design and there must not be any parts subject to wear
(chains, toothed belts etc.). If this is nevertheless the case, additional monitoring devices for the
mechanical connection of the sensors are required (e.g. monitoring a toothed belt).
If position processing is active, at least one absolute encoder must be used.
On the usage of two equivalent sensors it is to be ensured that the sensor with the higher resolution is
configured as sensor1 (
process sensor
) and the sensor with the lower resolution as sensor 2 (
reference
sensor
).
Safety instructions:
•
The GND connections for the encoders are to be connected to GND on the PSC1.
(See also chapter 5.8)
Содержание PSC1-C-10 Series
Страница 1: ...Installation manual for PSC1 modules Series PSC1 C 10 PSC1 C 10 SDMx PSC1 E 3x...
Страница 98: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 98 of 173 Version 57E 2 I 09 3 I 10 4 I 11...
Страница 140: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 140 of 173 Version 57E...
Страница 153: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 153 of 173 Version 57E Example for a hazard analysis...