schmersal PFB-SD-4M12-SD Скачать руководство пользователя страница 5

5

PFB-SD-4M12-SD

Operating instructions

Passive fieldbox

EN

4.4  DIP switch configuration and jumper

When you open the inspection window, ensure that no 

moisture or excessive humidity penetrates into the fieldbox.

The position of the DIP switch and the jumper is shown in black.

Fieldbox in the centre of a series circuit.

4 devices connected

O

N

1

8

7

6

5

4

3

2

No jumper set

All switches OFF

3 devices connected

O

N

1

8

7

6

5

4

3

2

Jumper 5/6 set

Switch 5+6 ON

2 devices connected

O

N

1

8

7

6

5

4

3

2

Jumper 3/4 set

Switch 3+4 ON

1 device connected

O

N

1

8

7

6

5

4

3

2

Jumper 1/2 set

Switch 1+2 ON

Last fieldbox in the series circuit

4 devices connected

O

N

1

8

7

6

5

4

3

2

Jumper 7/8 set

Switch 7+8 ON

3 devices connected

O

N

1

8

7

6

5

4

3

2

Jumper 5/6 and 7/8 set

Switch 5+6 and 7+8 ON

2 devices connected

O

N

1

8

7

6

5

4

3

2

Jumper 3/4 und 7/8 set

Switch 3+4 and 7+8 ON

1 device connected

O

N

1

8

7

6

5

4

3

2

Jumper 1/2 and 7/8 set

Switch 1+2 and 7+8 ON

The sealing labels available as an accessory can be used 

to seal the inspection window after the configuration has 

been checked.

4.5  Connector configuration

4.5.1 Connector configuration of device connection

PIN Colour* Signal Description of device signals

1

WH

A1

+24 VDC device supplied

2

BN

X1

Safety input 1

3

GN

A2

0 VDC device supply

4

YE

Y1

Safety output 1

5

GY

OUT

Diagnostic output

6

PK

X2

Safety input 2

7

BU

Y2

Safety output 2

8

RD

IN

Solenoid control

4.5.2 Connnector pin assignment Power IN & OUT of fieldbox

PIN Colour* Signal Description

1

BN

A1

+24 VDC device supplied

2

WH

A2

0 VDC device supply

3

BU

A2

0 VDC device supply

4

BK

A1

+24 VDC device supply

4.5.3 Connector pin assignment IN signals of the fieldbox

PIN Colour* Signal Description

1

BN

IN

Input SD interface

2

WH

Y1

Safety output 1

3

BU

OUT

Output SD interface

4

BK

Y2

Safety output 2

4.5.4 Connector pin assignment OUT signals of the Fieldbox

PIN Colour* Signal Description

1

BN

OUT

Output SD interface

2

WH

X1

Safety input 1

3

BU

IN

Input SD interface

4

BK

X2

Safety input 2

* Color code of SCHMERSAL M12 accessory cables

Содержание PFB-SD-4M12-SD

Страница 1: ...e passive fieldbox must only be used according to the following versions or for applications that are approved by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as w...

Страница 2: ...ith the relevant standards and the required safety level 2 3 Technical data Standards IEC 60947 1 Materials Enclosure polyamide PA 6 GF Inspection window polyamide PACM 12 Encapsulation polyurethane 2K PU Labelling plates polycarbonate PC Mechanical data Type of electrical connection Panel jack integrated socket Connection Connectors M12 8 pole A coded Power M12 Power 4 pole T coded IN OUT signals...

Страница 3: ...rs 101217788 2 5 m Connecting cable male female connectors 101217789 3 5 m Connecting cable male female connectors 103013428 5 0 m Connecting cable male female connectors 101217790 7 5 m Connecting cable male female connectors 103013429 3 3 2 Colour codes of the Schmersal cables M12 4 pole M12 8 pole PIN Conductor colour PIN Conductor colour 1 BN Brown 1 WH White 2 WH White 2 BN Brown 3 BU Blue 3 ...

Страница 4: ... 2 Input LED POWER LED Device connection 3 Input LED POWER LED Device connection 1 Input LED POWER LED Device connection 4 Input LED Connection Power IN Connection Power OUT Power LED fieldbox DIP switch fieldbox configuration Connection Out signals SD and safety signals Park position Jumper 2 Park position Jumper 1 Jumper fieldbox configuration Connection IN signals SD and safety signals ...

Страница 5: ...nd 7 8 set Switch 1 2 and 7 8 ON The sealing labels available as an accessory can be used to seal the inspection window after the configuration has been checked 4 5 Connector configuration 4 5 1 Connector configuration of device connection PIN Colour Signal Description of device signals 1 WH A1 24 VDC device supplied 2 BN X1 Safety input 1 3 GN A2 0 VDC device supply 4 YE Y1 Safety output 1 5 GY O...

Страница 6: ...DC 10A SD Out 0 VDC 24 VDC SD Out SD In FB 2 3 1 4 I O Power 2 1 3 4 I O SD O N 1 8 7 6 5 4 3 2 BK 4 BN 1 WH 2 WH 2 BU 3 BK 4 BU 3 BN 1 PLC Power supply Safety monitoring module Safety switchgear Fieldbox in the centre JP SW 7 8 OFF 4 devices connected JP SW 1 6 OFF SD Gateway Terminals Optional additional SD line ...

Страница 7: ...ive fieldbox EN I O Power 2 1 3 4 I O SD I O Power 2 1 3 4 I O SD O N 1 8 7 6 5 4 3 2 2 1 2 3 1 O N 1 8 7 6 5 4 3 2 Last fieldbox JP SW 7 8 ON 3 devices connected JP SW 5 6 ON Fieldbox in the centre JP SW 7 8 OFF 2 devices connected JP SW 3 4 ON ...

Страница 8: ...ly wiring and 10 A fuse protection Use of SCHMERSAL cables The cable lengths listed in the table between power supply and the 1st field box and between fieldboxes are maximum lengths Reducing the individual cable lengths is not critical Device configuration version Max number of devices Equals number of fieldboxes Length of the cable A up to the 1st fieldbox Length of the cables B between the fiel...