schmersal PDM-SD-4CC-SD Скачать руководство пользователя страница 6

6

Operating instructions

Passive distribution module

PDM-SD-4CC-SD

EN

4.7  Wiring example

 

Y2 Y1 A2 A1

A1 A2 X1 X2

A1

A2

X1

X2

I

O

Y1

Y2

Y2 Y1 A2 A1 I1 I2 I3 I4 O1 O2 O3 O4 A1 A2 X1 X2

A1

A2

X1

X2

I

O

Y1

Y2

Y2 Y1 A2 A1

A1 A2 X1 X2

A1

A2

X1

X2

I

O

Y1

Y2

Safety IN 2

Safety IN 1

0 VDC

+24 VDC

10A

O N

1

8

7

6

5

4

3

2

O N

1

8

7

6

5

4

3

2

O N

1

8

7

6

5

4

3

2

1

2

3

4

1

2

1

2

3

I1 I2 I3 I4 O1 O2 O3 O4

I1 I2 I3 I4 O1 O2 O3 O4

SD-Out

0 VDC

+24 VDC

SD-Out

SD-In

FB

PLC

Power  

supply

Safety  

monitoring

Safety  

switchgear

-  Module in middle  

SW 7 + 8 OFF

-  4 devices connected  

SW 1 - 6 OFF

-  Module in middle  

SW 7 + 8 OFF

-  2 devices connected  

SW 3 + 4 ON

-  Last module  

SW 7 + 8 ON

-  3 devices connected  

SW 5 + 6 ON

Terminals

Optional extra SD harness with distribution mo-

dules for additional safety function

SD Gateway

Содержание PDM-SD-4CC-SD

Страница 1: ...y be used in accordance with the following versions or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product...

Страница 2: ...D 4CC SD passive distribution module the secure OSSD outputs of the connected safety switchgear units are connected in series and wired to a relevant safety monitoring module The non secure SD interfa...

Страница 3: ...d condition It is possible to connect wires with and without conductor ferrules with a wire cross section of 0 25 mm to 1 5 mm to the terminals of the passive distribution module The supply voltage of...

Страница 4: ...device connection Pin assignment of safety switchgear connection Function safety switchgear Pin assignment of connector plug or conductor numbers Colour code of the Schmersal connector to DIN 47100 C...

Страница 5: ...2 A1 24 VDC device supplied I Device SD input O Device SD output A2 0 VDC device supplied X1 Safety input 1 X2 Safety input 2 Pin assignment of safety switchgear 2 Y1 Safety output 1 Y2 Safety output...

Страница 6: ...y IN 2 Safety IN 1 0 VDC 24 VDC 10A O N 1 8 7 6 5 4 3 2 1 2 3 4 I1 I2 I3 I4 O1 O2 O3 O4 SD Out 0 VDC 24 VDC SD Out SD In FB PLC Power supply Safety monitoring Safety switchgear Module in middle SW 7 8...

Страница 7: ...A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 Y2 Y1 A2 A1 I1 I2 I3 I4 O1 O2 O3 O4 A1 A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 O N 1 8 7 6 5 4 3 2 O N 1 8 7 6 5 4 3 2 1 2 1 2 3 I1 I2 I3 I4 O1 O2 O3 O4 Module in middle SW 7 8 O...

Страница 8: ...er supply wiring and 10 A fuse protection Use of SCHMERSAL cables The cable lengths listed in the table between power supply and the 1st module as well as between the modules are maximum lengths Reduc...

Отзывы: