Operating instructions

Passive distribution module

PDM-SD-4CC-SD

EN

4.3  Pin assignment of module connection

 

POWER

F4

F3

F2

F1

O N

1

8

7

6

5

4

3

2

Y1 Y2 A1 I O A2 X1 X2

2

4

3

1

I4

X1

O4

X2

I3

Y1

O3

Y2

I2

A2

O2

A2

I1

A1

O1

A1

4 7 1 8 5 3 2 6

2 level terminal

Input and output signals of safety switchgear

Safety signals and supply voltage

4 level terminal

Safety switchgear connection 4

Safety switchgear connection 3

Safety switchgear connection 2

Safety switchgear connection 1

M23 / M12 / M8 8-pin device connection

Pin assignment of safety switchgear connection

Function safety switchgear

Pin assignment of 

connector plug  

or conductor 

numbers

Colour code of the 

Schmersal connector  

to DIN 47100

Colour code of the 

Schmersal connector

Possible colour code of 

other commercially  

available connectors, also  

refer to IEC 60947-5-2

with conventional 

diagnostic output

with serial  

diagnostic function

from

 part no. 103007xxx

to

 part no. 103007xxx

A1

U

e

1

WH

BN

BN

X1 

Safety input 1

2

BN

WH

WH

A2

GND

3

GN

BU

BU

Y1 

Safety output 1

4

YE

BK

BK

OUT

Diagnostic output

SD output

5

GY

GY

GY

X2 

Safety input 2

6

PK

VT

PK

Y2 

Safety output 2

7

BU

RD

VT

IN 

Solenoid control

SD input

8

RD

PK

or

without function

9

Содержание PDM-SD-4CC-SD

Страница 1: ...y be used in accordance with the following versions or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product...

Страница 2: ...D 4CC SD passive distribution module the secure OSSD outputs of the connected safety switchgear units are connected in series and wired to a relevant safety monitoring module The non secure SD interfa...

Страница 3: ...d condition It is possible to connect wires with and without conductor ferrules with a wire cross section of 0 25 mm to 1 5 mm to the terminals of the passive distribution module The supply voltage of...

Страница 4: ...device connection Pin assignment of safety switchgear connection Function safety switchgear Pin assignment of connector plug or conductor numbers Colour code of the Schmersal connector to DIN 47100 C...

Страница 5: ...2 A1 24 VDC device supplied I Device SD input O Device SD output A2 0 VDC device supplied X1 Safety input 1 X2 Safety input 2 Pin assignment of safety switchgear 2 Y1 Safety output 1 Y2 Safety output...

Страница 6: ...y IN 2 Safety IN 1 0 VDC 24 VDC 10A O N 1 8 7 6 5 4 3 2 1 2 3 4 I1 I2 I3 I4 O1 O2 O3 O4 SD Out 0 VDC 24 VDC SD Out SD In FB PLC Power supply Safety monitoring Safety switchgear Module in middle SW 7 8...

Страница 7: ...A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 Y2 Y1 A2 A1 I1 I2 I3 I4 O1 O2 O3 O4 A1 A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 O N 1 8 7 6 5 4 3 2 O N 1 8 7 6 5 4 3 2 1 2 1 2 3 I1 I2 I3 I4 O1 O2 O3 O4 Module in middle SW 7 8 O...

Страница 8: ...er supply wiring and 10 A fuse protection Use of SCHMERSAL cables The cable lengths listed in the table between power supply and the 1st module as well as between the modules are maximum lengths Reduc...

Отзывы: