schmersal MAF/S 441-11Y Скачать руководство пользователя страница 3

3

EN

MAF/S 441

Operating instructions
Level switches for bulk materials

5.  Applications

5.1  Applications

Image 3: Level monitoring silo

Image 4: Material low monitoring

Image 5:  Level monitoring  

transport duct

Image 6: Storage level monitoring

6.  Maintenance

6.1  Maintenance

In case of correct installation in accordance with the above-described 
instructions, the component requires little maintenance. By use in 
extreme conditions, we recommend routine maintenance including the 
following steps:
1. Check the free movement of the actuating element
2. Remove particles of dust and soiling
3. Check the correct fixing of the cover screws
4. Check for damages and correct fixing
5.  Check cable entry and connections in a de-energised condition
6. Lubricate the shaft or plunger (if necessary)

7.  Disposal

7.1  Disassembly

The product must be disassembled in a de-energised condition only. 

7.2  Disposal

The product must be disposed of in an appropriate manner in  
accordance with the national prescriptions and legislations.

Содержание MAF/S 441-11Y

Страница 1: ...rised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can...

Страница 2: ...Switchover time 35 ms Bounce duration 5 ms Ambient temperature 30 90 C Mechanical life 1 million operations Switching frequency max 3000 h Actuating speed max 1 m s min 1 mm s 3 Mounting 3 1 General mounting instructions Fitting is only authorised in a de energised condition Two mounting holes are available The use of a protective ground wire is imperative 3 2 Dimensions All measurements in mm PG1...

Страница 3: ...use in extreme conditions we recommend routine maintenance including the following steps 1 Check the free movement of the actuating element 2 Remove particles of dust and soiling 3 Check the correct fixing of the cover screws 4 Check for damages and correct fixing 5 Check cable entry and connections in a de energised condition 6 Lubricate the shaft or plunger if necessary 7 Disposal 7 1 Disassembl...

Страница 4: ...ernet http www schmersal com br 8 Appendix 8 1 EC Declaration of conformity Name of the component MAF S 441 11y Description of the component Level switches Relevant EC Directives 2006 95 EG EC Low Voltage Directive Place and date of issue Boituva October 27 2014 Authorised signature Marco Antonio De Dato Head of Engineering and Design EC Declaration of conformity Translation of the original Declar...

Отзывы: