schmersal EX-Z/T 235 Скачать руководство пользователя страница 2

2

Operating instructions
Position switches

EX-Z/T 235

EN

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages resul-
ting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

EX-

➀➁

 

235-

Z

-

-

-

-3D

No.

Option

Description

Z

Snap action A

T

Slow action A

Actuator selection, refer to catalogue

02

2 NC contacts

11

1 NO contacts / 1 NC contacts

20

2 NO contacts

H

Slow action with staggered contacts

UE

Slow action with overlapping contacts

1297

Enclosure with transverse slotted holes

2138

Roller lever 7H for safety applications

1637

Gold-plated contacts

In accordance with the Machinery Directive, the type plate of 
safety components is type plate is labelled "safety compo-
nent".

Only if the information described in this operating instruc-
tions manual are realised correctly, the safety function and 
therefore the compliance with the Machinery Directive and 
the Explosion Protection Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The safety switches are suitable for hinged or sliding guards, which 
need to be closed in order to provide for the necessary operational 
safety. The components can be used in explosion-endangered areas of 
Zone 2 and 22 equipment category 3 GD. The installation and mainte-
nance requirements to the standard series EN 60079 must be met.

Conditions for safe operation

Due to the specific impact energy, the components must be fitted with a 
protection against mechanical stresses. The specific ambient tempe-
rature range must be observed. The user must provide for a protection 
against the permanent influence of UV rays.

The user must evaluate and design the safety chain in ac-
cordance with the relevant standards and the required safety 
level.

2.4  Technical data

Equipment category:

 

L

 II 3GD

Ex protection:

 

Ex tc IIIC T90°C Dc X, Ex nC IIC T5 Gc X 

Standards:

 

EN 60947-5-1, EN 60079-0, EN 60079-15,  

EN 60079-31, BG-GS-ET-15

Design: 

fixings to EN 50047

Enclosure: 

zinc die-cast, enamel finish

Max. impact energy:

 

1 J

Actuating speed:

 

max. 1 ms 

Protection class:

 

IP67 to EN 60529

Contact material:

 Silver

Contact type: 

change-over with double break Zb,  

or 2 NC contacts, galvanically separated contact bridges

Switching system:

 

A

 EN 60947-5-1, slow or snap action, NC contacts 

with positive break

Connection:

 

screw terminals

Cable section:

 

min. 0.75 mm²; max. 2.5 mm²; 

solid and stranded wire with conductor ferrules

Cable entry:

 

M20 x 1.5

Rated impulse withstand voltage U

imp

:

 

6 kV

Rated insulation voltage U

i

:

 

500 V

Thermal test current I

the

:

 

10 A

Utilisation category:

 

AC-15 / DC-13

Rated operating voltage/ 

 

Rated operating current I

e

/U

e

:

 

4 A / 230 VAC;  

1 A / 24 VDC

Max. fuse rating:

 

6 A gG D-fuse

Required short-circuit current:

 

1000 A

Ambient temperature:

 

 –20 °C … + 60 °C

Mechanical life:

 

20 million operations

Switching frequency: 

max. 5000 / h

Max. Actuating speed:

 

1 m/s

Bounce duration:

 

slow action: < 3 ms;  

snap action: in accordance with actuating speed

Switchover time: 

slow action: in accordance with actuating speed

Cable cross-section of the cable glands

min. Ø 7 mm;  

max. Ø 12 mm

Cable glands: 

L

 II 2GD

Tightening torque

  

- Cover screws:

 

min. 0.6 Nm  

- Cable gland:

 

min. 8 Nm

2.5  Safety classification

Standards:

 

EN ISO 13849-1

B

10d

 (NC contact):

 20,000,000

B

10d

 (NO contact)  

at 10% ohmic contact load:

 1,000,000

Service life: 

20 years

MTTF

B

d

x

x

h

s/h

3600

d

10d

op

op

op

n

0,1 x n

op

t

cycle

(Specifications can vary depending on the application-specific parame-
ters h

op

, d

op

, t

cycle

 as well as the load.)

Содержание EX-Z/T 235

Страница 1: ... below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention ru...

Страница 2: ...inte nance requirements to the standard series EN 60079 must be met Conditions for safe operation Due to the specific impact energy the components must be fitted with a protection against mechanical stresses The specific ambient tempe rature range must be observed The user must provide for a protection against the permanent influence of UV rays The user must evaluate and design the safety chain in...

Страница 3: ...n the technical data Please observe the remarks of the standards EN ISO 12100 EN 953 and EN ISO 14119 3 2 Dimensions All measurements in mm Position switches EX Z T 235 22 15 30 20 30 63 5 8 5 20 4 3 Mounting of the actuating heads Repositioning the actuating heads R 1R 4R K 3K 4K V H The actuating head can be repositioned by 4 x 90 Unscrew the four screws of the actuating head Philips tip profile...

Страница 4: ...g to the instructions The connection is executed correctly The cable is correctly executed and connected Check the free movement of the actuating element The safety component is not damaged Remove particles of dust and soiling Check cable entry and connections in de energised condition 5 2 Maintenance In case of correct installation in accordance with the above described instructions the component...

Страница 5: ...ective ATEX Afixing of the CE conformity mark 1 for safety components whose type plate is labelled safety component 2 for position switches without safety function Used harmonized standards EN 60947 5 1 EN 60079 31 EN 60079 0 EN 60079 15 Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal October 7 2014...

Страница 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Отзывы: