schmersal EX-BNS 303-2187 Скачать руководство пользователя страница 3

3

EX-BNS 303-2187

Operating instructions

Safety sensor

EN

3.  Mounting

3.1  General mounting instructions

• Fitting is only authorised in a de-energised condition

•  Screw both nuts in the provided mounting holes to fix the safety 

sensor (max. tightening torque 300 Ncm)

• Do not use the sensor and the actuator as a mechanical backstop

•  Any mounting position, provided that the active surfaces and signs  

on it are opposite

•  Inseparably fix the safety sensor and the actuator to the safety guard

•  Do not install the safety sensor and the actuator in strong magnetic 

fields

•  If possible, do not install the safety sensor and the actuator on 

ferromagnetic material.

•  Do not subject the safety sensor and actuator to extreme vibrations 

and shocks.

•  Keep away from metal chips

•  The mounting distance between two sensors should always be at 

least 50 mm.

Please observe the specifications for the maximum impact 

energy in the technical data.

Safety sensor and actuator must be permanently fitted to the 

safety guards and protected against displacement by suitable 

measures (tamperproof screws, gluing, drilling of the screw 

heads).

3.2  Dimensions

All measurements in mm.

Safety sensor with cable

44

M

30

x

1,5

1000

6

36

Actuator

BPS 300

2

30

15

90

°

14

ø

2

ø

4,

5

BPS 303

15

2

14

ø

2

ø

37

ø

30

BPS 303 SS

2

1,5

13,8

15

M4

ø

30

ø

37

Actuator BPS 303 and BPS 303 SS

The actuators are primarily provided for use in the food-processing 

industry and therefore are not labelled.

The actuators are fixed by means of the supplied tamper-proof screws. 

The mounting hole must have a diameter of 4.5 mm. Next to the 

mounting hole, a second mounting hole must be provided. This hole is 

used for the fixture of the displacement protection dowel.

Position of the dowel: refer to the image in chapter "Axial misalignment".

3.3  Axial misalignment

A horizontal and vertical misalignment of the safety sensor and the 

actuator is tolerated. The possible misalignment depends on the 

distance of the active surfaces of the sensor and the actuator.  

The sensor remains active within the tolerance range.

The specified switching distances refer to opposedly mounted safety 

sensors and actuators.

0,5

0

1

2

3

4

5

1

2

3,5

4

3

5

7

9

10

assured switching distance:

s

ao

 = 5 mm

Assured switch-off distance

s

ao

 = 15 mm

3.4  Adjustment

The LED can only be used as rough setting tool. The correct 

functionality of both safety channels must be checked by means of  

the connected safety-monitoring module.

Отзывы: