schmersal EX-AZM 415 Скачать руководство пользователя страница 4

4

Operating instructions

Solenoid interlock

EX-AZM 415

EN

Power to lock

EX-AZM 415-11/11ZPKA…-3D

EX-AZM 415-11/02ZPKA…-3D

S1

A2

S2

P

A1

23 11

24 12

13
21

14
22

P

S1

A2

S2

P

A1

23 11

24 12

11
21

12
22

P

EX-AZM 415-11/20ZPKA…-3D

EX-AZM 415-02/11ZPKA…-3D

S1

A2

S2

P

A1

13
23

14
24

23 11

24 12

P

S1

A2

S2

P

A1

P

21  11

22 12

13
21

14
22

EX-AZM 415-02/02ZPKA… -3D

EX-AZM 415-02/20ZPKA…-3D

P

S1

A2

S2

P

A1

21  11

22 12

11
21

12
22

S1

A2

S2

P

A1

P

21  11

22 12

13
23

14
24

Legend:

A

 positive break

 Monitoring the interlock according to ISO 14119

P

 actuated

Q

 not actuated

Information for the selection of suitable safety-monitoring 

modules can be found in the Schmersal catalogues or in the 

online catalogue on the Internet: www.schmersal.net. 

5.  Set-up and maintenance

5.1  Functional testing

The safety function of the safety components must be tested.  

The following conditions must be previously checked and met:

- The installation is executed according to the instructions

- The connection is executed correctly

- The cable is correctly executed and connected

- The safety component is not damaged

- Remove particles of dust and soiling

- Check cable entry and connections

5.2  Maintenance

In case of correct installation in accordance with the instructions 

described above, the component requires little maintenance. For use in 

extreme conditions, we recommend routine maintenance including the 

following steps:

1.   Check the correct fixing of the actuator and the safety switchgear

2. Remove particles of dust and soiling

3.  Check cable entry and connections in a de-energised condition

 Do not open the device when live.

Adequate measures must be taken to ensure protection 

against tampering either to prevent tampering of the safety 

guard, for instance by means of replacement actuators.

Damaged or defective components must be replaced.  

For explosion protection reasons, the component must be 

exchanged after max. 1 million operations.

6.  Disassembly and disposal

6.1  Disassembly

The safety switchgear must be disassembled in a de-energised 

condition only.

6.2  Disposal

The safety switchgear must be disposed of in an appropriate manner in 

accordance with the national prescriptions and legislations.