Operating instructions

Fail-safe delay timer

AZS 2305

EN

6.  Set-up and maintenance

6.1  Functional testing

The safety function of the safety-monitoring module must be tested. 

The following conditions must be previously checked and met:

1. Correct fitting of the safety-monitoring module

2. Fitting and integrity of the power cable

6.2  Maintenance

In the case of correct installation and adequate use, the safety-

monitoring module features maintenance-free functionality.

A regular visual inspection and functional test, including the following 

steps, is recommended:

• Check the correct fixing of the safety monitoring module

• Check the cable for damage.

Damaged or defective components must be replaced.

7.  Disassembly and disposal

7.1  Disassembly

The safety monitoring module must be disassembled in the de-

energised condition only.

7.2  Disposal

The safety monitoring module must be disposed of in an appropriate 

manner in accordance with the national prescriptions and legislations.

AZS 2305

L1

A1

100mA

S13

K1

14

24

34

A2

max.

Y1

Y2

3

K2

S14

S21

S22

13

23

33

+24 VDC

0 V

0 V

M

E

S

H2

L1

K3

K4

+24 VDC

N

N

0

H1

AES 1235

14

A1

100mA

S13

K1

A2

max.

Y1

X1

K2

S14

S21

S22

13

23

24

A1

A2

Y2

X2

0 V

A1

A2

14

13

21

22

33

34

41

42

51

52

63

64

AZM 161

8.  Appendix

8.1  Wiring example

The application examples shown are suggestions. They however do not 

release the user from carefully checking whether the switchgear and its 

set-up are suitable for the individual application.

Monitoring of a sliding, hinged or removable safety guard with a 

solenoid interlock of the AZM 161 series. The safety guard monitor of 

the series AES monitors the position of the safety guard.

The wiring diagram is shown with guard doors closed and in a de-

energised condition. Inductive loads (e.g. contactors, relays, etc.) are to 

be provided with suitable interference suppression circuitry.

Key

E

  Unlock solenoid interlock

R

Optional:  Safety guard must not be opened after the release

S

Optional:  Feedback circuit increases the safety,  

but not the control category

H

Start button (optional)

To be observed for AC variants: AC supply through A1-A2, 

GND of the internal 24 VDC control voltage is on terminal PE.