C2: Manual release by means of triangular key TK-M5
The manual release must be protected against accidental actuation, e.g. by using the enclosed seal after
completing commissioning.
3.3 Emergency exit -T/-T8 or emergency release -N
With variants that have both emergency exit and emergency release, the red lever is loosely supplied. Before first
use, mount the lever on the triangular part of the release using the screw supplied so that the arrow in the triangle
and pin on the red lever are congruent.
The installation of the lever is possible on both sides. The opposite side can be used as a manual release by means
of a triangular key TK-M5.
2
Reset of the manual release by actuating the red emergency exit lever must be prevented by the user.
2
Emergency exit (-T/-T8)
(fitting and actuation only from within the hazardous area)
To activate the emergency exit, turn the red lever in the direction of the arrow to the end stop. The safety outputs
switch off and the guard system can be opened. The blocked position is cancelled by turning the lever in the
opposite direction. In the unlocked position, the guard system is secured against unintentional locking.
2
Emergency release (-N)
Fitting and actuation only from outside the hazardous area. The emergency release should only be used in an emergency.
The solenoid interlock should be installed and/or protected so that an inadvertent opening of the interlock by an
emergency release can be prevented. The emergency release must be clearly labelled that it should only be used in an
emergency. The label can be used that was included in the delivery.
To activate the emergency release turn the red lever in the direction of the arrow to the end stop. The safety
outputs switch off and the guard system can be opened. The lever is latched and cannot be returned to its original
position. To cancel the blocking condition, the central mounting screw must be loosened to such extent that the
lever can be turned back into its original position. The screw must then be re-tightened.