11
AZM300
Operating instructions
Solenoid interlock
EN
Wiring example 2: Series-wiring of the AZM300 with serial diagnostic function
The safety outputs of the first safety component are wired to the safety-monitoring module. The serial Diagnostic Gateway is connected to the serial
diagnostic input of the first safety component.
max. 31 components in series
24 VDC
GND
1
2
3
5
4
6
8
X1
Y1
X2
SD IN
SD OUT
1
2
3
5
4
6
8
X1
Y1
X2
7
Y2
7
Y2
SD IN
SD OUT
X1
Y1
X2
Y2
SD IN
SD OUT
Y1
Y2
SD IN
24V GND
24V GND
Safety outputs → evaluation
Gateway → Field bus
9.2 Wiring configuration and connector accessories
Function safety switchgear
Pin configuration of
the connector
5
8
4
3
2
1
7
6
Colour codes of the
Schmersal connectors
Poss. colour codes
of other customary
connectors
With conventional
diagnostic output
With serial diagnostic
function
IP67 / IP69
to DIN 47100
IP69K
(PVC)
to
IEC 60947-5-2: 2007
A1
U
e
1
WH
BN
BN
X1
Safety input 1
2
BN
WH
WH
A2
GND
3
GN
BU
BU
Y1
Safety output 1
4
YE
BK
BK
OUT
Diagnostic output
SD output
5
GY
GY
GY
X2
Safety input 2
6
PK
VT
PK
Y2
Safety output 2
7
BU
RD
VT
IN
Solenoid control
SD input
8
RD
PK
OR
Connecting cables with coupling (female)
IP67 / IP69, M12, 8-pole – 8 x 0.25 mm²
to DIN 47100
Connecting cables with coupling (female)
IP69K, M12, 8-pole – 8 x 0.21 mm²
Cable length
Ordering code
Cable length
Ordering code
2.5 m
5.0 m
10.0 m
15.0 m
103011415
103007358
103007359
103011414
5.0 m
5.0 m, angled
10.0 m
101210560
101210561
103001389