EN
Operating instructions pages 1 to 2
Original
AZM-Y-8P-IO
AZM-Y-A-8P-IO
Operating instructions
Y-adapter and terminating plug
EN
1
Product description
Purpose
The Y-adapter AZM-Y-8P-IO makes it possible to connect in series
electronic solenoid interlocks and sensors in the series AZM, MZM
and RSS
For this purpose the safety channels are connected in series The
IN inputs as well as the diagnostic outputs OUT are connected in
parallel The terminating plug AZM-Y-A-8P-IO supplies the safety
channels with the operating voltage M12 cable extensions can be
used for the wiring Please note that voltage losses could occur (due
to cable length, cable section, voltage drop / solenoid interlock) This
aspect limits the maximum number of solenoid interlocks and sensors
connected in series
The electrical connection may only be carried out by
authorised personnel in a de-energised condition
Technical data
Operating voltage SD device:
24 VDC (–15%/+10%)
Rated operating voltage adapter:
30 VDC
Maximum operating current device connection:
1 A
Fuse rating for the supply cable (cable protection):
4 A
Ambient temperature T
u
:
– 25 ºC … + 75 °C
Recommended tightening torque:
- Connection side:
10 Nm
- For the fastening screws:
12 Nm
x
000 / 03
2018 / v
A
- 103025640-EN /
A / 2018-03-13 /
AE-Nr
-
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
wwwschmersalnet
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications
Wiring example
AZM-Y-A-8P-IO
AZM-Y-8P-IO
AZM-Y-8P-IO
AZM-Y-8P-IO
1
2
1
2
1
2
AZM-Y-8P-IO
AZM-Y-8P-IO
AZM-Y-8P-IO AZM-Y-A-8P-IO