schmersal AZM 200D Скачать руководство пользователя страница 7

7

AZM 200D

Operating instructions

Safety switch with interlocking function

EN

8.2  Wiring configuration and connector accessories

Function  
safety switchgear

Pin configuration of the 

connector

Colour code or  

conductor numbering  

of the below-mentioned  

Schmersal connectors

Possible colour code of other  

commercially available connectors

to EN 60947-5-2: 2007

DIN 47100

A1

U

e

1

BN

1

BN

WH

OUT

Diagnostic output

2

WH

2

WH

BN

A2

GND

3

BU

3

BU

GN

Y1 

Safety output 1

4

BK

4

BK

YE

Y3

Safety output 3

5

GY

5

GY

GY

Y4

Safety output 4

6

VT

6

PK

PK

Y2 

Safety output 2

7

RD

7

VT

BU

IN

Solenoid control

8

PK

8

OR / shielded

RD

LED

LED+

9

9

Button

Input/output

10

10

Button

Input/output

11

11

NC

-

12

12

Connector plug ST1 M23, (8+1)-pole

Connector plug ST2 M12, 8-pole

Connector plug ST3 M23, 12-pole

1

2

9

3

4

5

6

7

8

5

8

4

3

2

1

7

6

10

12

11

9

8

7

6

5

4

3

2

1

Connecting cables with female connector 

IP67, M23, (8+1)-pole - 8 x 0.75 mm²

Connecting cables with female connector 

IP67, M12, 8-pole - 8 x 0.23 mm²

Connecting cables with female connector 

IP67, M23, 12-pole - 12 x 0.75 mm²

Cable length

Part number

Cable length

Part number

Cable length

Part number

5.0 m

10.0 m

1209959

1209958

2.5 m

5.0 m

10.0 m

1209963

1209964

1209960

5.0 m

1208520

Colour code key
Code

Colour

Code

Colour

Code

Colour

Code

Colour

BK

black

GN

green

PK

pink

WH

white

BN

brown

GY

grey

RD

red

YE

yellow

BU

blue

OR

orange

VT

violet

Содержание AZM 200D

Страница 1: ...re machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country ...

Страница 2: ...control category 3 or opened PL e control category 4 and maintaining the safe switched off condition of the safety outputs for as long as the safety guard is open Interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk since the safety guard can be opened immediately on failure of the power supply or upon activation of the main swi...

Страница 3: ... Any mounting position The mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided The unused actuator opening must be sealed by means of the dust proof flap included in delivery Please observe the remarks of the standards EN ISO 12100 EN 953 and EN 1088 The constructor must provide for the necessary strain relief of the connections Admissibl...

Страница 4: ...rol In the power to unlock version of the AZM 200 the safety switch is unlocked when the IN signal 24V is set In the power to lock version of the AZM 200 the safety switch is locked when the IN signal 24 V is set 5 1 Safety switch with diagnostic output Mode of operation of the safety outputs The unlocking of the safety switch causes the safety outputs Y3 and Y4 to be disabled As long as the actua...

Страница 5: ...f On 24 V 24 V 24 V 0 V 24 V Error warning1 solenoid interlock locked 0 V 24 V On Flashes 2 On 24 V1 24 V1 24 V 0 V 0 V Error 0 V 24 V 24 V 0 V On Flashes 2 Off 0 V 0 V 24 V 0 V 0 V 1 after 30 min disabling due to fault 2 refer to flash code Table 2 flash codes red LED Flash codes red Designation Autonomous switch off after Error cause 1 flash pulse Error warning at output Y1 30 min Fault in outpu...

Страница 6: ...tor 2 Remove particles of dust and soiling 3 Check cable entry and connections Damaged or defective components must be replaced 7 Disassembly and disposal 7 1 Disassembly The safety switchgear must be disassembled in a de energised condition only 7 2 Disposal The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 8 Appendix...

Страница 7: ...trol 8 PK 8 OR shielded RD LED LED 9 9 Button Input output 10 10 Button Input output 11 11 NC 12 12 Connector plug ST1 M23 8 1 pole Connector plug ST2 M12 8 pole Connector plug ST3 M23 12 pole 1 2 9 3 4 5 6 7 8 5 8 4 3 2 1 7 6 10 12 11 9 8 7 6 5 4 3 2 1 Connecting cables with female connector IP67 M23 8 1 pole 8 x 0 75 mm Connecting cables with female connector IP67 M12 8 pole 8 x 0 23 mm Connecti...

Страница 8: ...ions Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards EN 60947 5 1 2004 AC 2005 A1 2009 EN 60947 5 3 2013 ISO 14119 2013 EN ISO 13849 1 2008 AC 2009 EN 61508 Teile 1 7 2010 EN 62061 2005 AC 2010 A1 2013 Notified body for the prototype test TÜV Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype tes...

Отзывы: