background image

5

EN

AZ17i-B-EN

AZ 17 I

Operating instructions

Safety switch

7. EU Declaration of conformity

Name of the component:

AZ 17 I

Type:

See ordering code

Description of the component:

Positive break position switch with  

separate actuator for safety functions

Relevant Directives:

Machinery Directive

RoHS-Directive

2006/42/EC

2011/65/EU

Applied standards:

DIN EN 60947-5-1:2010,

DIN EN ISO 14119:2014

Person authorized for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

Place and date of issue:

Wuppertal, March 14, 2016

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

Содержание AZ 17 I

Страница 1: ...s listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident prevent...

Страница 2: ...control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data Standards IEC 60947 5 1 BG GS ET 15 Enclosure glass fibre reinforced thermo plastic self extinguishing Actuator stainless steel 1 4301 Coding level according to ISO 14119 high Protection class IP67 to IEC 60529 Contact material Silver Contact type change over with double break ...

Страница 3: ... the actuator d d R min R min Actuating radius over the wide edge of the actuator The axis of the hinge must be d mm above and in a parallel plane to the top surface of the safety switch The basis setting provides a minimum radius of Rmin Actuator B6L B6R b a a b b a a b b a a b The B6L or B6R actuators are set to the smallest radius in factory To increase the radius the setting screws a b must be...

Страница 4: ...t up and maintenance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Check for correct installation of the actuator and the switch 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 5 2 Maintenance In case of correct installation in accordance with the inst...

Страница 5: ...on authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal March 14 2016 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Internet www schmersal com We hereby certify that the hereafter described components...

Страница 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Отзывы: