background image

AZ 16ZI

Operating instructions

Safety switch

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded when safety switchgear is 

used. The relevant requirements of the standard ISO 14119 

must be observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3.2  Mounting of the actuator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.3  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .4

4.2  Contact variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7  EU Declaration of conformity

09.2016 / 573358 / P

DE

Betriebsanleitung  . . . . . . . . . . . . . . .Seiten 1 bis 6

Original

Содержание AZ 16zi

Страница 1: ...rsions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident pr...

Страница 2: ...s and the required safety level The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data Standards IEC 60947 5 1 Enclosure glass fibre reinforced thermoplastic self extinguishing Actuator stainless steel 1 4301 Coding level according to ISO 14119 high Actuating speed 2 m s Max switching frequency 4000 h Prot...

Страница 3: ...fety switch in which the actuator hook is inserted refer to table Note The ball latch 2053 must be adjusted after the switch is fitted to the safety guard Uniformly adjust the screws of the ball latch by means of a screwdriver to this effect Actuating radii d R min d R min Rmin mm d mm Rmin mm d mm B6L 120 11 60 11 B6R 120 11 60 11 B1 B1 1747 B1 2024 B1 2053 B1 2177 Key d d R min R min Actuating r...

Страница 4: ...C AZ 16 12ZI ST 1 NO 2 NC with connector 11 21 33 12 22 34 11 21 31 12 22 32 3 2 1 4 5 6 7 8 S11 S21 S33 S12 S22 S34 Information about the switch travel can be found in the online catalogue on the Internet www schmersal net 5 Set up and maintenance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Check ...

Страница 5: ...ereafter described components both in their basic design and construction conform to the applicable European Directives Name of the component AZ 16ZI Type See ordering code Description of the component Positive break position switch with separate actuator for safety functions Relevant Directives Machinery Directive RoHS Directive 2006 42 EC 2011 65 EU Applied standards DIN EN 60947 5 1 2010 DIN EN...

Страница 6: ...ax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Production site ACE Schmersal Eletroeletrônica Industrial Ltda Av Brasil nº 815 Jardim Esplanada CEP 18550 000 Boituva SP Brazil Phone 55 0 15 32 63 9866 Fax 55 0 15 32 63 9890 E Mail vendas schmersal com br Internet http www schmersal com br ...

Отзывы: