schmersal AES 3075 Скачать руководство пользователя страница 5

5

AES 3075

Operating instructions

Safety-monitoring module

EN

8.2  Integral System Diagnostics (ISD)

The LED indication of the safety-monitoring modules shows the 

different switching conditions and errors. The following tables show the 

different switching conditions.

Tables switching condition indication

Diagnostic LED

System condition

The LED is green.

Enabling circuit Y14 und Y 24 "high"

LED flashes green

Enable delay time running

The LED is yellow

At least one safety guard open

LED flashes yellow

The feedback circuit is open.
The enabling input X4 is open.

Table error indications

Indication  

(orange) LED

Error

Cause

1 impulse

 

Error safety 
guard 1

Defective supply 
voltage lead, defective 
switch, erroneous 
fitting of the switch; 
switch only partially 
actuated* for at least 5 
s; cross-wire short

2 impulses

 

Error safety 
guard 2

Refer to error 
safety guard 1

3 impulses

 

Error safety 
guard 3

Refer to error 
safety guard 1

4 impulses

 

Error safety 
guard 4

Refer to error 
safety guard 1

5 impulses

Enabling outputs 
Y14 and Y24

Cross-wire short; 
Short-circuit

6 impulses

 

Additional 
transistor outputs 
Y1-Y5

Short-circuit

7 impulses

Interference 
signals at the 
inputs

 Too high capacitive or 
inductive interference 
at the inputs or the 
supply voltage lead, no 
safe evaluation 

8 impulses

Feedback circuit 

Defective feedback 
message of the 
external contactors, 
erroneous wiring of the 
feedback circuit

*  Partial actuation: position of the switch, in which only one contact was actuated.

Deleting the error message

The error message is deleted once the fault has been rectified and 

after the connected switches have been actuated to check the various 

functions (open and then close the safety guard).

Содержание AES 3075

Страница 1: ...hine or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country...

Страница 2: ... The safety monitoring module has a redundant structure Two microprocessors build the heart of the safety monitoring module The enabling outputs for connecting the external positive guided contactors as well as all inputs of the safety monitoring module are monitored and evaluated by both microprocessors The five additional transistor outputs are short circuit proof and can be used for signalling ...

Страница 3: ...an be individually set for each safety guard by means of jumpers on the board refer to Settings drawing S21 S22 always is a NC contact Contact combinations NC NC contact jumper inside NO NC contact jumper outside factory setting Settings S1 S3 S2 S4 4 4 4 4 3 2 1 Key 1 Board 2 Jumper 3 Enable delay time 4 Contact type additional transistor outputs Y1 high safety guard 1 open Y2 high safety guard 2...

Страница 4: ...S22 S21 S22 S13 K4 3 Y5 S13 S13 S14 S14 S21 24VDC 0V 0V M Y1 Y2 S Y14 Y3 Y24 Y4 S1 S2 S3 S4 max H6 Monitoring of four safety guards cascading by means of a magnetic safety sensor of the BNS series If less than 4 switches are connected the unused terminals S21 S22 must be bridged before a NC contact is connected This applies to the position of the jumpers in the safety monitoring module with NC NO ...

Страница 5: ... partially actuated for at least 5 s cross wire short 2 impulses Error safety guard 2 Refer to error safety guard 1 3 impulses Error safety guard 3 Refer to error safety guard 1 4 impulses Error safety guard 4 Refer to error safety guard 1 5 impulses Enabling outputs Y14 and Y24 Cross wire short Short circuit 6 impulses Additional transistor outputs Y1 Y5 Short circuit 7 impulses Interference sign...

Страница 6: ...8 Köln ID n 0340 EU prototype test certificate ET 16122 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal The currently valid declaration of conformity can be downloaded from the internet at www schmersal net Place and date of issue Wuppertal November 10 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of co...

Отзывы: