schmersal AES 1337 Скачать руководство пользователя страница 4

4

Operating instructions

Safety-monitoring module

AES 1337

EN

6.  Set-up and maintenance

6.1  Functional testing

The safety function of the safety-monitoring module must be tested. 

The following conditions must be previously checked and met:

1. Correct fixing

2. Check the integrity of the cable entry and connections

3.  Check the safety-monitoring module's enclosure for damage.

4.  Check the electrical function of the connected sensors and their 

influence on the safety-monitoring module and the downstream 

actuators

6.2  Maintenance

A regular visual inspection and functional test, including the following 

steps, is recommended:

1. Check the correct fixing of the safety-monitoring module

2. Check the cable for damages

3. Check electrical function

The device has to be integrated into the periodic check-ups 

according to the Ordinance on Industrial Safety and Health, 

however at least 1x/year.

Damaged or defective components must be replaced.

7.  Disassembly and disposal

7.1  Disassembly

The safety-monitoring module must be disassembled in a de-energised 

condition only.

Push up the bottom of the enclosure and hang out slightly tilted 

forwards.

7.2  Disposal

The safety-monitoring module must be disposed of in an appropriate 

manner in accordance with the national prescriptions and legislations.

8.  Appendix

8.1  Wiring examples

The application examples shown are suggestions. They however do not 

release the user from carefully checking whether the switchgear and its 

set-up are suitable for the individual application.

The wiring diagram is shown with guard doors closed and in a  

de-energised condition. Inductive loads (e.g. contactors, relays, etc.) 

are to be provided with suitable interference suppression circuitry. 

AES 1337 (Fig. 2)

Guard door monitoring by means of a magnetic safety sensor (BNS)

A1

A2

S13 S14 S21 S22 X1 X2

13

14

N

a)

23

24

33

L1

34 Y1

K1

K1

F1

Ui

K2

K2

3

M

K3

K4

H

S

A

X3

24 VDC

0V

=

Fig. 2

a) Logic

H

  Start button

Содержание AES 1337

Страница 1: ...nce with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description To avoid EMC disturbances the physical ambient and operational conditions at the place where the product is installed must meet the provisions laid down in the paragraph Electromagnetic Compatibility EMC o...

Страница 2: ...a PFH value assessment also refer to chapter 2 5 Safety classification Control category 4 PL e to DIN EN ISO 13849 1 corresponds to SIL 3 to DIN EN 61508 2 SILCL 3 to DIN EN 62061 To determine the Performance Level PL of the entire safety function e g sensor logic actuator to DIN EN ISO 13849 1 an analysis of all relevant components is required 2 4 Technical data General data Standards IEC EN 6020...

Страница 3: ...IN rail and push up until it latches in position 3 2 Dimensions All measurements in mm Device dimensions H W D 100 x 22 5 x 121 mm 4 Electrical connection 4 1 General information for electrical connection As far as the electrical safety is concerned the protection against unintentional contact of the connected and therefore electrically interconnected apparatus and the insulation of the feed cable...

Страница 4: ...lth however at least 1x year Damaged or defective components must be replaced 7 Disassembly and disposal 7 1 Disassembly The safety monitoring module must be disassembled in a de energised condition only Push up the bottom of the enclosure and hang out slightly tilted forwards 7 2 Disposal The safety monitoring module must be disposed of in an appropriate manner in accordance with the national pre...

Страница 5: ...ossible Dual channel control of magnetic safety switches to EN 60947 5 3 Fig 7 Wire breakage and earth leakage in the control circuits are detected Cross wire shorts between the monitoring circuits are detected Category 4 PL e to DIN EN ISO 13849 1 possible S22 S21 S14 S13 S22 S21 S14 S13 S22 S14 S21 S13 Fig 5 Fig 6 Fig 7 The connection of magnetic safety switches to the AES 1337 safety monitoring...

Страница 6: ...Zertifizierungsstelle Elektrotechnik Gustav Heinemann Ufer 130 50968 Köln ID n 0340 EC prototype test certificate ET 16102 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal November 8 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH ...

Отзывы: