Schmalz X-Pump
Brief operating instructions
S
CHMALZ
4-25
Internal cycle counters [ct1], [ct2], [ct3]
The ejector system has various internal counters.
Counter 1 is incremented with each external signal on the control line
SUC-
TION
and thus counts the suction cycles. In the case of ejectors with pulse
valves, each valid suction pulse is counted.
Counter 2 is incremented each time the internal suction valve changes state.
The difference between Counter 2 and Counter 1 can thus be used to find out
how often vacuum air saving function has been executed.
Counter 3 counts the number of faults which caused the diagnostic output to be
activated.
The counters can be reset with the aid of the menu.
counter
> 3 Sekunden
Counter values
displayed in blocks of
three digits.
The 4 output LEDs
identify the blocks.
X * 10
0
X * 10
9
as above
as above
X * 10
0
X * 10
0
>3 seconds
blinking
counter
> 3 Sekunden
Counter values
displayed in blocks of
three digits.
The 4 output LEDs
identify the blocks.
X * 10
0
X * 10
9
as above
as above
X * 10
0
X * 10
0
>3 seconds
blinking
F
UNCTIONS OF THE CYCLE COUNTERS
Symbol
Function
Remarks
Counter 1
Counter for suction cycles (external signal)
Counter 2
Counter for valve actuation frequency
Counter 3
Counter for air saving function (evacuation-time
faults, external diagnostic signal)