Operation
36 / 50
EN-US · 30.30.01.01610 · 00 · 01/20
CAUTION
Risk of injury due to collision!
4
Walk behind the lifting device in the direction of travel while maintaining the pre-
scribed safe distances.
Observe the following while a load is lifted:
•
Never transport loads above people.
•
Do not operate unless you have a clear view of the whole working area.
•
Keep the lifting device as close to the floor as possible.
•
Adapt the travel speed to the conditions and avoid jerky movements.
7.10 Setting Down the Load
1. Before releasing the load, ensure that it can-
not slip or tilt.
2. Press the locking button
and slide the man-
ual slide valve (3) in the
direction against
the force of the spring.
3
1
3
ð
The lifting device can now be released from the load.
7.11 Draining Water from the Vacuum Pump
4
After the final lifting cycle, let the vacuum pump continue to run for 5 minutes to avoid
corrosion.
ð
Accumulated water in the vacuum pump is discharged.
7.12 Parking the Lifting Device
NOTE
Damage to suction plates due to inappropriate storage position!
4
Do not set the lifting device down on the suction plates.
Options for correct parking:
1. Switch off the vacuum generator.
2. Disconnect the power supply.
3. Set the lifting device down on its parking feet (optional) or on suitable parking equipment.