Description of Functions
34 / 68
EN-US · 30.30.01.01961 · 00 · 06/19
If you cannot remember the correct PIN code, read or reset the PIN code from the IO-Link, or
use NFC to reset to factory settings.
8.13 Restricting Access Using Device Access Locks [0x000C]
In IO-Link mode, the "Device Access Locks" default parameter is available to prevent changes to parame-
ter values using the operating element of the ejector.
A menu lock using the Device access locks parameter has a higher priority than the menu PIN. In other
words, this lock cannot be bypassed by entering a PIN, and remains in place.
It can only be canceled using IO-Link, not on the ejector itself.
8.14 Restricting Access with Extended Device Access Locks [0x005A]
The Extended Device Access Locks gives you the following options:
•
Block all NFC access or restrict it to read-only functions. The NFC lock using the extended device ac-
cess locks parameter has a higher priority than the NFC PIN. That means that this lock also cannot be
bypassed by entering a PIN.
•
Block the use of manual mode.
•
Block the transmission of IO-Link events.
8.15 Resetting to Factory Settings (Clear All) [0x0002]
This function is used to reset the following configurations to their factory settings:
•
The configuration of the ejector
•
The initial setup
•
The production setup profile settings
•
The IO-Link parameter "Application specific tag"
This function is executed using the parameter [
rE5
] in the EF menu or via IO-Link.
The factory settings for the ejector are listed in the Technical Data section.
WARNING
By activating/deactivating the product, output signals lead to an action in the pro-
duction process!
Personal injury
4
Avoid possible danger zone.
4
Remain vigilant.
A description of how to reset the ejector to factory settings using the display and operating element fol-
lows:
ü
The EF menu is open.
1. Use the
button to select the parameter [
rE5
].
2. Confirm using the
button.
3. Use the
button to select [
YE5
] for the parameter value.
4. Confirm using the
button.
ð