![Schmalz SBX-C 200 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/schmalz/sbx-c-200/sbx-c-200_operating-instructions-manual_1212874029.webp)
MAINTENANCE
30.10.02.00604/02
www.schmalz.com
EN | 29
9.2 Maintenance Schedule
Interval
Daily Weekly Monthl
y
Every six
months
Annual
check
Does the blower make strange noises when a full load is
picked up?
X
X
Has the dust filter been cleaned?
X
X
Is the electrical installation still OK? Is the cable screw
union secure?
X
Regrease the blower bearings according to the
operating instructions for the blower
See the operating instructions for the blower
Are the vacuum hoses in good condition (not brittle, not
kinked, no worn sections and no leaks)?
X
X
Check that all the connections are secure, e.g. the
screws, hose clamps, etc.
X
Are the type plate and maximum load plate still attached
to the device?
X
Are the operating instructions available and are workers
familiar with them?
X
Check all load-bearing parts (e.g. suspension) for
deformation, wear or other damage.
X
X
Check the sealing mats for
wear, tears and leaks. Replace
if necessary.
X
X
General condition of the device
X
Leak Test
X
X
Check the storage and suction chambers for
contamination
They may only be cleaned by trained and instructed
specialist personnel/the manufacturer
The interval depends on the
application/ambient conditions.
We recommend checking the contamination
within the suction bar for the first time in the
first month after start of operations (2-shift
operation).
video
www.schmalz.com/
sealing-foam-
replacement