Installation
EN-US · 30.30.01.02084 · 02 · 12/20
41 / 72
9.3 Pneumatic Connection
CAUTION
Compressed air or vacuum in direct contact with the eye
Severe eye injury
4
Wear eye protection
4
Do not look into compressed air openings
4
Do not look into the silencer air stream
4
Do not look into vacuum openings, e.g. suction cups
CAUTION
Noise pollution due to incorrect installation of the pressure and vacuum connec-
tions
Hearing damage
4
Correct installation.
4
Wear ear protectors.
9.3.1 Connecting the Compressed Air and Vacuum
1
2
1
Compressed air connection
2
Vacuum connection
The 1/4" thread compressed air connection is marked with the number 1 on the ejector.
4
Connect the compressed air hose. The max. tightening torque is 4 Nm.
The 1/2" thread vacuum connection is marked with the number 2 on the ejector.
4
Connect the vacuum hose. The max. tightening torque is 4 Nm.