General Description of Functions
EN-US · 30.30.01.02084 · 02 · 12/20
31 / 72
4. Press the
for more than 3 seconds.
ð
The ejector is reset to the factory settings.
ð
The display flashes for a number of seconds and then returns to display mode.
The function for resetting factory settings does not affect the following elements:
•
The counter readings
•
The zero-point adjustment of the sensor
•
The IO-Link parameter “Application Specific Tag”
•
The production setup profiles, which are currently deactivated
The factory settings for the ejector are listed in the Technical Data section.
7.19 Counters
The ejector has two internal counters, [
cc1
] and [
cc2
], which cannot be erased:
Counter 1 increases with each valid pulse at the “suction” signal input, meaning that it counts all the suc-
tion cycles during the ejector’s service life. Counter 2 increases each time the “suction” valve is switched
on. As a result, the average switching frequency of the air saving function can be determined using the
difference between counters 1 and 2.
Designation
Display parameter
Description
Counter 1
[
cc1
]
Counter for suction cycles (“suc-
tion” signal input)
Counter 2
[
cc2
]
Counter for the “suction valve”
switching frequency
Displaying a Counter on the Operating Panel of the Ejector:
ü
Select the counter you wish to see in the system menu.
4
Confirm the counter by pressing the
button.
ð
The last three decimal places of the counter total are displayed (the digits x10
0
). This corresponds to
the least significant three digits. The decimal point at the far right lights up. This corresponds to the
least significant three digits.
Use the
and
buttons to display the remaining decimal places of the counter total. The decimal
points show which three-digit block of the complete counter value is shown on the display.
The counter total is comprised of the 3 number blocks together:
Displayed section
10
6
10
3
10
0
Digit block
0.48
61.8
593.
The current counter total in this example is 48 618 593.
7.20 Displaying the Software Version
The software version indicates the software currently running on the internal controller.
7.21 Displaying the Part Number
The part number of the ejector is specified on the label and also stored electronically.
ü
In the system menu, select the parameter
Art
.
1. Confirm using the
button.
ð
The first two digits of the part number are displayed.