Maintenance
EN-US · 30.30.01.01484 · 00 · 01/21
55 / 72
3. Install any cleaned or new nozzle in the cor-
rect position. Ensure that the O-ring is fitted.
O-Ring
13.5 Replacing the Press-In Screens
The vacuum and compressed air connections of the ejectors contain press-in screens. Dust, chippings and
other solid materials may be deposited in the screens over time.
4
If you notice that the performance of the ejectors has declined, replace the screens.
13.6 Replacement of the Device with a Parameterization Server
The IO-Link protocol provides an automated process for transferring data when a device is replaced. For
this Data storage mechanism, the IO-Link master mirrors all setting parameters for the device in a sepa-
rate non-volatile memory. When a device is swapped for a new one of the same type, the setting parame-
ters for the old device are automatically saved in the new device by the master.
ü
The device is operated on a master with IO-Link version 1.1 or higher.
ü
The Data storage feature in the configuration of the IO-Link port is activated.
4
Ensure that the new device is restored to the factory settings
before
it is connected to the IO-Link
master. If necessary, reset the device to the factory settings.
ð
The device parameters are automatically mirrored in the master when the device is configured using
an IO-Link configuration tool.
ð
Changes to the parameters made in the user menu on the device or via NFC are mirrored in the mas-
ter.
Changes to the parameters made by a PLC program using a function module are
not
automatically mir-
rored in the master.
4
Manually mirroring data: After changing all the required parameters, execute ISDU write access to
the “System Command” parameter [0x0002] using the command “Force upload of parameter data
into the master” (numerical value 0x05) (see Data Dictionary).
Use the Parameterization server function of the IO-Link master to ensure that no data is lost
when switching the device.