5. Product description
42 | 194
Reference Manual |Edition 5.0 (09-2016) |
CoaxCenter 6000
Air supply
Maintenance unit
The machine must for the correct functioning of the feeding and the individual stations be supplied
with compressed air. Also opening and closing the safety cover is controlled pneumatically. The com-
pressed air is supplied to the maintenance unit on the left side of the machine, where the main pres-
sure is reduced.
The length of the hose for the compressed air supply should not exceed 15 m. Use the hose with a
diameter of 12 mm supplied with the machine.
The following modules/stations are controlled by compressed air:
■
Safety cover:
open/close
■
Feeding unit:
Contact pressure feeding belts
■
Gripper of swivel arm:
Clamping force
■
Air jet unit:
Blow away wire residue on the cutting unit
■
Stacker:
Extending the tray for removing the batches
■
Collector station:
Contact pressure of picker
The maximal operating pressure should be
adjusted on the pressure valve
1
, to not higher
than 7 bar (0.7 MPa). Likewise the minimal pres-
sure should not be bellow 5 bar (0.5 MPa), oth-
erwise the safety cover can not be opened or
closed properly.
The set up operational pressure can be read on
the pressure gauge.
As the compressed air contains residual mois-
ture, the emerging condensation is separated in
the water separator
2
. The water separator can
be drained via the blow-off valve
3
.
At the output, the pressure reduced and cleaned
air is supplied to the machine.
Compressed air control
On this dials the operating pressure for the fol-
lowing stations is set-up:
■
Gripper swivel arm
1
■
Feeding unit
2
The pressure depends on the to be processed raw material. The pressure should be set as low as pos-
sible, to ensure that the raw material is fed properly but with no marks on the insulation.
1
2
3
1
2
Содержание CoaxCenter 6000
Страница 4: ...Topic list 4 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 10: ...Table of contents 10 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 22: ...3 Transportation 22 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 48: ...5 Product description 48 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 78: ...7 General handling operation 78 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 98: ...8 Programming of articles production 98 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 101: ...9 Configuration settings Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 101 194 Backlight AOI collecting area...
Страница 110: ...10 User interface user levels 110 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 122: ...11 Diagnostics troubleshooting 122 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 154: ...15 Decommissioning disposal 154 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 155: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 155 194 APPENDIX...
Страница 161: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 161 194...
Страница 162: ...16 Appendix 162 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 16 2 PNEUMATIC SCHEMA...
Страница 163: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 163 194...
Страница 174: ...16 Appendix 174 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 186: ...16 Appendix 186 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 187: ...Personal notes Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 187 194...
Страница 188: ...Personal notes 188 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Страница 193: ......
Страница 194: ......