XCA 1100 / XCA 1200 Control Unit
22
Operating Manual XCA 1100 / XCA 1200
●
Version 12/17
Table 8:
LED displays on the
controller
(continuation)
Designation
Colour Status
Meaning
STAT
SERCOS phases
red
on
SERCOS phase 0
red
flashing
SERCOS phase 1
yellow
flashing
SERCOS phase 2
green
flashing
SERCOS phase 3
on
SERCOS phase 4
EXT STAT
SERCOS error
red
off
No error
on
Communication error
flashing
Drive error
Error messages are saved in the active error buffer and the error
logbook and have error numbers and additional information.
The active error buffer and logbook can be called on any operating
level using the <Ctrl+?> key combination.
4.2
Ethernet and Sercos III LED Displays
Table 9:
LED displays at the
Ethernet and Sercos-III
socket connectors (5x
RJ45)
Bezeichnung Farbe Zustand Bedeutung
ETH (3x)
LED 1
Duplex
off
No network connection,
no activity or10
Mbits/s
grün
on
100 MBit/s Full Duplex operation
LED 2
Link / Activity / Speed
off
No network connection
gelb
flashing
100 MBit/s connetction aktiv
grün
flashing
10 MBit/s connection aktiv
sercos III
LED 1
(2x)
Link
off
No network connection
grün
on
Collision
LED 2
Activity
off
no activity
gelb
flashing
100 MBit/s connection aktiv