XCA 1100 / XCA 1200 Control Unit
18
Operating Manual XCA 1100 / XCA 1200
●
Version 12/17
4.1.4
X10
– DVI Interface
The monitor interface is designed as a DVI-I (single link with 18+5
contacts). Both digital and, via a DVI AGA adapter, analogue monitors
can be operated.
Table 5:
Pin assignment of
DVI interface X10
DVI-I socket
connector
Single link
Pin
Designation
Explanation
1
TDMS data 2-
Digital red minus (link 1)
2
TDMS data 2+
Digital red plus (link 1)
3
TDMS data 2/4 shield
Shield data 2,4
4
nc
Not connected
5
nc
Not connected
6
DDC clock
DDC clock pulse
7
DDC data
DDC data
8
Analogue vertical sync
V sync
9
TDMS data 1-
Digital green minus (link 1)
10
TDMS data 1+
Digital green plus (link 1)
11
TDMS data 1/3 shield
Shield data 1,3
12
nc
Not connected
13
nc
Not connected
14
+5V
15
Ground
Ground for 5 V
16
Hotplug detect
17
TDMS data 0-
Digital blue minus (link 1)
18
TDMS data 0+
Digital blue plus (link 1)
19
TDMS data 0/5 shield
Shield data 0.5
20
nc
Not connected
21
nc
Not connected
22
TDMS clock shield
Shield clock pulse
23
TDMS clock+
Clock pulse plus
24
TDMS clock-
Clock pulse minus
C1
Analogue red
Analogue red
C2
Analogue green
Analogue green
C3
Analogue blue
Analogue blue
C4
Analogue horizontal sync
H sync
C5
Analogue ground
Ground